System Start Up
Step A–
Turn on water supply at angle stop and open the Adapt-
A-Valve™ . Turn faucet handle to the open position to start
the flow of water through the unit . Run 3 gallons of water
through the unit in order to flush out the normal black car-
bon fines (it will “sputter” until the air is purged out) from the
unit . Initially, the water may appear cloudy which is due to
tiny air bubbles and it will clear up shortly . Close the faucet
when finished .
Step B –
Check for leaks . If you have any leaks, shut off the water
supply to your system, tighten any fittings / housings and
restart unit .
NOTICE
Check frequently over the next 24 hours to ensure no leaks are
present
6-Month System Maintenance
Replace:
• (1) Sediment Filter
• (1) Carbon Block Filter
• (1) UF Membrane Filter
NOTICE
Your UF Drinking Water Module is equipped with valved heads
which will automatically turn off the water supply to each filter
when the filter is released, thus you do not need to turn off the
incoming water supply at the Adapt-A-Valve™. The faucet must
be off when filters are replaced.
Step A –
Place the towel under the UF Drinking Water Module to
catch any excess water that drips out from the filters during
the changeover .
Step B –
To remove a filter cartridge:
Rotate the filter 1/4-turn
clockwise . Pull the cartirdge
downward (from filter head) to
remove . Dispose of old filter
Step C –
To install a filter cartridge: Ori-
ent the cartridge with the label
facing to the left (9 o’clock
positon) . Push the cartridge
into the head and rotate 1/4-
turn counter-clockwise
Step D –
Repeat this procedure for the
2nd filter cartridges . When
finished, flush your system
completely once to remove any natural carbon fines from
the UF Drinking system . Check over the next 24 hours to
ensure no leaks are present .
Parts List
ITEM #
PART #
DESCRIPTION
1
F560080
ADAPT-A-VALVE™
2
PE-08-BI-0500FW
1/4" WHITE TUBING
3
WQCSC11
SEDIMENT FILTER
4
WQCCC11
CARBON BLOCK FILTER
5
WQCHFC11
UF FILTER
6
F116023
NON AIR-GAP FAUCET - CHROME
1
5
3
6
4
2
2
HOT
COLD
SINK
TO
INSTALL
TO
REMOVE
6