 System Start Up

Step A– 

 Turn on water supply at angle stop and open the Adapt-

A-Valve™ . Turn faucet handle to the open position to start 

the flow of water through the unit . Run 3 gallons of water 

through the unit in order to flush out the normal black car-

bon fines (it will “sputter” until the air is purged out) from the 

unit . Initially, the water may appear cloudy which is due to 

tiny air bubbles and it will clear up shortly . Close the faucet 

when finished .

Step B – 

 Check for leaks . If you have any leaks, shut off the water 

supply to your system, tighten any fittings / housings and 

restart unit .

NOTICE

Check frequently over the next 24 hours to ensure no leaks are 

present

 6-Month System Maintenance

Replace:

• (1) Sediment Filter 
• (1) Carbon Block Filter 
• (1) UF Membrane Filter

NOTICE

Your UF Drinking Water Module is equipped with valved heads 

which will automatically turn off the water supply to each filter 

when the filter is released, thus you do not need to turn off the 

incoming water supply at the Adapt-A-Valve™. The faucet must 

be off when filters are replaced. 
Step A – 

 Place the towel under the UF Drinking Water Module to 

catch any excess water that drips out from the filters during 

the changeover .

Step B – 

 To remove a filter cartridge: 

Rotate the filter 1/4-turn 

clockwise .  Pull the cartirdge 

downward (from filter head) to 

remove .  Dispose of old filter

Step C – 

 To install a filter cartridge: Ori-

ent the cartridge with the label 

facing to the left (9 o’clock 

positon) .  Push the cartridge 

into the head and rotate 1/4-

turn counter-clockwise

Step D – 

 Repeat this procedure for the 

2nd filter cartridges . When 

finished, flush your system 

completely once to remove any natural carbon fines from 

the UF Drinking system . Check over the next 24 hours to 

ensure no leaks are present .

 

 Parts List

ITEM #

PART #

DESCRIPTION

1

F560080

ADAPT-A-VALVE™

2

PE-08-BI-0500FW

1/4" WHITE TUBING

3

WQCSC11

SEDIMENT FILTER

4

WQCCC11

CARBON BLOCK FILTER

5

WQCHFC11

UF FILTER

6

F116023

NON AIR-GAP FAUCET - CHROME

1

5

3

6

4

2

2

HOT

COLD

SINK

TO
INSTALL

TO
REMOVE

6

Содержание WQCFU-T-11KIT

Страница 1: ...follow any attached instructions or operating parameters may lead to the product s failure Keep this Manual for future reference WARNING Do not use with water that is microbiologically unsafe or of un...

Страница 2: ...ment plants and hospitals however through advances in technology it is now available to you as a powerful under sink water filtration plant in your home Ultra filtration is capable of running at low w...

Страница 3: ...bility for damage resulting from the installation of faucet Step A Determine desired location for the RO faucet on your sink and place a piece of masking tape on over where the hole is to be drilled...

Страница 4: ...Cutting Cut the tube square It is essential that the outside diameter be free of score marks and that burrs and sharp edges be removed before inserting into fitting Connecting Make certain to push the...

Страница 5: ...Valve NOTICE NOTICE STEP 3 Adapt A Valve Installation For 1 2 Configuration D B LINE FROM ANGLE STOP VALVE FAUCET CONNECTION FAUCET LINE ANGLE STOP VALVE C B A D B LINE FROM ANGLE STOP VALVE FAUCET C...

Страница 6: ...lter is released thus you do not need to turn off the incoming water supply at the Adapt A Valve The faucet must be off when filters are replaced Step A Place the towel under the UF Drinking Water Mod...

Страница 7: ...ng Temperature Maximum 100 F 38 C Minimum 40 F 4 4 C 3 Operating Water Pressure Maximum 85 psi 5 98 kg cm Minimum 20 psi 1 41 kg cm 3 Maximum flow Rate 0 50 gpm 1 89 lpm 4 Rated Capacity 2 000 Gallons...

Страница 8: ...rranty LIMITATIONS AND EXCLUSIONS WATTS WILL NOT BE RESPONSIBLE FOR ANY IMPLIED WAR RANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WATTS WILL NOT BE RESPONSIBLE FOR AN...

Отзывы: