background image

Start-Up Instructions SXT

The water conditioner should be installed with the inlet, outlet, and 

drain connections made in accordance with the manufacturer’s 

recommendations, and to meet applicable plumbing codes .
1 .  Program the valve control according to instructions shown in this 

manual .

2 .  Start an immediate regeneration by holding the Extra Cycle 

button for 5 seconds . Position the valve to backwash . Ensure the 

drain line flow remains steady for 10 minutes or until the water 

runs clear .

3 .  Position the valve to the brine / slow rinse position . Ensure the 

unit is drawing water from the brine tank (this step may need to 

be repeated) . Not used on SXT filter systems .

4 .  Position the valve to the rapid rinse position . Check the drain line 

flow, and run for 5 minutes or until the water runs clear .

5 .  Position the valve to the start of the brine tank fill cycle . Ensure 

water goes into the brine tank at the desired rate . The brine valve 

drive cam will hold the valve in this position to fill the brine tank 

for the first regeneration . Not used on SXT filter systems .

6 .  Replace control cover .
7 .  Put salt in the brine tank . Not used on SXT filter systems .

Do not use granulated or rock salt .

Timer Features SXT

Figure 4 

A. Features of the SXT

•  Power backup that continues to keep time and the passage of 

days for a minimum of 48 hours in the event of power failure . 

During a power outage, the control goes into a power-saving 

mode . It does not monitor water usage during a power failure, 

but it does store the volume remaining at the time of power 

failure .

•  Settings for both valve (basic system) and control type (method 

used to trigger a regeneration) .

•  Day-of-the-Week controls .
•  While in service, the display alternates between time of day, 

volume remaining or days to regeneration .

•  The Flow Indicator flashes when outlet flow is detected . 
•  The Service Icon flashes if a regeneration cycle has been 

queued .

Meter, volume, and capacity values are not displayed on SXT filter 

systems .

•  A Regeneration can be triggered immediately by pressing the 

Extra Cycle button for five seconds .

•  The Parameter Display displays the current Cycle Step (BW, 

BF, RR etc) during regeneration, and the data display counts 

down the time remaining for that cycle step . While the valve 

is transferring to a new cycle step, the display will flash . The 

parameter display will identify the destination cycle step (BW, 

BF, RR, etc) and the data display will read "------" . Once the 

valve reaches the cycle step, the display will stop flashing 

and the data display will change to the time remaining . During 

regeneration, the user can force the control to advance to the 

next cycle step immediately by pressing the extra cycle button .

B. Setting the Time of Day

1 .  Press and hold either the Up or Down buttons until the 

programming icon replaces the service icon and the parameter 

display reads TD .

2 .  Adjust the displayed time with the Up and Down buttons .
3 .  When the desired time is set, press the Extra Cycle button to 

resume normal operation . The unit will also return to normal 

operation after 5 seconds if no buttons are pressed .

Figure 5 

C. Queueing a Regeneration

1 .  Press the Extra Cycle button . The service icon will flash to 

indicate that a regeneration is queued .

2 .  To cancel a queued regeneration, press the Extra Cycle button .

D. Regenerating Immediately

Press and hold the Extra Cycle button for five seconds .

NOTICE

NOTICE

9                                    W110 LXT Downflow Softeners and SXT Filters

Содержание W110 LXT

Страница 1: ... Diagrams 26 Troubleshooting LXT 28 Troubleshooting SXT 29 Job Specification Sheet 30 NOTES 31 WARNING Read this Manual BEFORE using this equipment Failure to read and follow all safety and use information can result in death serious personal injury property damage or damage to the equipment Keep this Manual for future reference You are required to consult the local building and plumbing codes pri...

Страница 2: ...00 15 15 7 310 NOTE Brine tanks come with safety float valve CHART 2 W110 Series Backwashing Micro Z Filters With SXT Timers MODEL NO VALVE PIPE SIZE IN TANK SIZE MEDIA CU FT PEAK SERVICE FLOW GPM BACKWASH GPM FLOOR SPACE L x W x H SHIP WT LBS NM09 W110 W110 1 9 x 48 1 9 7 16 x 10 x 55 110 NM10 W110 W110 1 10 x 54 1 5 10 7 16 x 11 x 62 140 NM12 W110 W110 1 12 x 52 2 15 12 17 x 13 x 60 200 NM14 W11...

Страница 3: ...BACKWASH GPM FLOOR SPACE L x W x H SHIP WT LBS NC09 W110 W110 1 9 x 48 1 4 4 16 x 10 x 55 80 NC10 W110 W110 1 10 x 54 1 5 6 5 16 x 11 x 62 105 NC12 W110 W110 1 12 x 52 2 8 7 17 x 13 x 60 145 NC14 W110 W110 1 14 x 65 3 11 10 18 x 15 x 74 200 NC16 W110 W110 1 16 x 65 4 14 12 20 x 17 x 74 265 CHART 6 W110 Series Backwashing Empty Filters With SXT Timers MODEL NO VALVE PIPE SIZE IN TANK SIZE MEDIA CU ...

Страница 4: ...side down or drop Turning the tank upside down or laying the tank on its side can cause media to enter the valve Use only regenerants designed for water conditioning Do not use ice melting salt block salt or rock salt During cold weather it is recommended that the installer warm the valve to room temperature before operating Teflon is a trademark of E I duPont de Nemours How To Use This Manual Thi...

Страница 5: ...ions 1 Turn off water heater s 2 Turn off the main water supply to the home and open an inside faucet cold and hot to relieve any pressure within the plumbing system 3 Place the system in the desired installation location Make sure that the location is level and sturdy enough to support the weight of the system once it is in operation 4 Place the bypass valve in the bypass position 5 Connect the c...

Страница 6: ...r Size BLFC Size US FT3 Metric Liters 8 0 75 20 000 0 125 9 25 000 0 125 9 1 00 30 000 0 125 10 1 25 35 00 0 125 10 1 50 40 00 0 125 12 45 00 0 125 12 1 75 50 00 0 125 12 2 00 55 0 0 25 13 60 0 0 25 13 2 25 65 0 0 25 14 2 50 70 1 0 25 14 75 1 0 25 14 2 75 80 1 0 25 14 3 00 85 1 0 25 14 3 25 90 2 0 50 14 95 2 0 50 14 3 50 100 2 0 50 16 3 75 105 3 0 50 16 110 3 0 50 16 4 00 115 3 0 50 W110 LXT Downf...

Страница 7: ...ton for 5 seconds Position the valve to backwash Ensure the drain line flow remains steady for 10 minutes or until the water runs clear 3 Position the valve to the brine slow rinse position Ensure the unit is drawing water from the brine tank this step may need to be repeated 4 Position the valve to the rapid rinse position Check the drain line flow and run for 5 minutes or until the water runs cl...

Страница 8: ...n 3 Press the Extra Cycle button once to advance valve to Regeneration Cycle Step 2 brine draw slow rinse 4 Press the Extra Cycle button once to advance valve to Regeneration Cycle Step 3 rapid rinse 5 Press the Extra Cycle button once to advance valve to Regeneration Cycle Step 4 brine refill 6 Press the Extra Cycle button once more to advance the valve back to in service NOTE If the unit is a fi...

Страница 9: ...thod used to trigger a regeneration Day of the Week controls While in service the display alternates between time of day volume remaining or days to regeneration The Flow Indicator flashes when outlet flow is detected The Service Icon flashes if a regeneration cycle has been queued Meter volume and capacity values are not displayed on SXT filter systems A Regeneration can be triggered immediately ...

Страница 10: ...he valve in service While in the Program Mode the control continues to operate normally monitoring water usage and keeping all displays up to date Control programming is stored in memory permanently G Manually Initiating a Regeneration 1 When timer is in service press the Extra Cycle button for 5 seconds on the main screen 2 The timer advances to Regeneration Cycle Step 1 backwash and begins progr...

Страница 11: ...timer range is 5 100 liters 6 Hold the Extra Cycle button until the Program icon disappears to save your programming 7 If you are just changing one program step hold the Extra Cycle button until the Program icon disappears to save your changes If you do not hold the Extra Cycle button until the Program icon disappears your changes will not be saved This unit has a day of the week reserve It calcul...

Страница 12: ...ot hold the Extra Cycle button until the Program icon disappears your changes will not be saved This unit has a day of the week reserve It calculates a reserve for each day of the week based on the past 4 weeks D W110 Filter Time Clock Time of Day Time of Backwash Backwash Length Days Between Regens Days to Backwash Resin PM MODE Figure 10 1 Press the Mode button to advance to Time of Backwash Pus...

Страница 13: ...of software D Downflow U Upflow A1 Displays the average water usage for day 1 in cubic meters A2 Displays the average water usage for day 2 in cubic meters A3 Displays the average water usage for day 3 in cubic meters A4 Displays the average water usage for day 4 in cubic meters A5 Displays the average water usage for day 5 in cubic meters A6 Displays the average water usage for day 6 in cubic met...

Страница 14: ...s reserve DO Day Override The system s day override setting RT Regen Time The time of day the system will regenerate BW BD RR BF Regen Cycle Step Times The time duration for each regeneration step Adjustable from OFF and 0 199 minutes NOTE If Othr is chosen under Valve Type then C1 C2 C20 will be displayed along with available cycle steps RR BD SR BW RF SP LC denotes the Last Cycle D1 D2 D3 D4 D5 ...

Страница 15: ...seconds while in normal Service mode This resets all parameters to the system default values Not reset are the volume remaining in meter immediate or meter delayed systems and days since regeneration in the time clock system Master Reset Hold the Extra Cycle button while powering up the unit This resets all of the parameters in the unit Check and verify the choices selected in Master Programming M...

Страница 16: ...n set to one of the metered options Use the Up and Down buttons to adjust the value as needed Figure 17 Range 1 199 grains mg l 7 Reserve Selection Display Code RS Press the Extra Cycle button Use this display to set the Safety Factor and to select the type of reserve to be used in your system This setting is identified by RS in the upper left hand corner of the screen The reserve selection parame...

Страница 17: ...r left hand corner of the screen The abbreviations used are listed below Abbreviation Cycle Step BD Brine Draw BF Brine Fill AD Air Draw BW Backwash RR Rapid Rinse SV Service If the system has been configured with the Other valve type the regeneration cycles will be identified as C1 C2 C20 Cycle steps can be programmed in any order using the Up or Down buttons with the following selections Up to 2...

Страница 18: ...wn buttons to select one of the 8 available settings Abbreviation Description P0 7 3 4 Paddle Wheel Meter t0 7 3 4 Turbine Meter P1 0 1 Paddle Wheel Meter t1 0 1 Turbine Meter P1 5 1 5 Paddle Wheel Meter t1 5 1 5 Turbine Meter P2 0 2 Paddle Wheel Meter Gen Generic or Other non Fleck Meter Figure 26 16 Meter Pulse Setting Display Code K Press the Extra Cycle button Use this display to specify the m...

Страница 19: ...ay to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen Figure 28 3 Press the Extra Cycle button Use this display to adjust the Regeneration Time This option setting is identified by RT in the upper left hand corner of the screen Figure 29 4 Press the Extra Cycle button Use this display to adjust the Feed Water Hardness This option setting ...

Страница 20: ...setting is identified by FR in the upper left hand corner of the screen Figure 33 3 Press the Up button Use this display to view the Peak Flow Rate since the last regeneration cycle This option setting is identified by PF in the upper left hand corner of the screen Figure 34 4 Press the Up button Use this display to view the Hours in Service since the last regeneration cycle This option setting is...

Страница 21: ...1 61832 00 Cover Assembly Black Blue 2 1 61836 Panel Gear Assembly Downflow Upflow 3 1 E Timer 4 1 61835 Motor Assembly Call your distributor for part number MODE jdofue jdofue jdofue jdofue jdofue jdofue 1 2 3 4 21 W110 LXT Downflow Softeners and SXT Filters ...

Страница 22: ...Item No QTY Part No Description 1 1 61832 00 Cover Assembly Black Blue 2 1 61836 Panel Gear Assembly Downflow Upflow 3 1 61834 Timer Assembly SXT 4 1 61835 Motor Assembly 1 2 3 4 W110 LXT Downflow Softeners and SXT Filters 22 ...

Страница 23: ...06 DLFC Plastic 0 60 gpm 1 2 3 4 Item No QTY Part No Description 60705 08 DLFC Plastic 0 80 gpm 60705 10 DLFC Plastic 1 0 gpm 60705 12 DLFC Plastic 1 2 gpm 60705 13 DLFC Plastic 1 3 gpm 60705 15 DLFC Plastic 1 5 gpm 60705 17 DLFC Plastic 1 7 gpm 60705 20 DLFC Plastic 2 0 gpm 60705 24 DLFC Plastic 2 4 gpm 60705 30 DLFC Plastic 3 0 gpm 60705 35 DLFC Plastic 3 5 gpm 60705 40 DLFC Plastic 4 0 gpm 6070...

Страница 24: ...40 Yoke 1 Sweat 13708 45 Yoke 3 4 Sweat 19275 Yoke Angle 90 Deg 3 4 NPT 19275 45 Yoke Angle 90 Deg 3 4 Sweat 19620 01 Yoke Assy 3 4 R Angle 90 Deg w O rings Clips Screws 40636 Yoke 1 1 4 NPT 40636 49 Yoke 1 1 4 Sweat 41027 01 Yoke 3 4 NPT Cast Machined 41026 01 Yoke 1 NPT Cast Machined SS 41026 02 Yoke 1 BSP Cast Machined SS 18706 10 Yoke 1 BSP Plastic 41027 02 Yoke 3 4 BSP Cast Machined 18706 12 ...

Страница 25: ... x 0 75 4 1 19805 Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 Plastic 10 1 18312 Retainer Drain 11 1 60014 Safety Brine Valve Assy 2310 12 2 10150 Grommet 0 30 Dia 13 1 60068 8 06 Float Assy 2310 w 8 06 Rod 60068 10 5 Float Assy 2310 w 10 5 Rod 60068 11 5 Float Assy 2310 w 11...

Страница 26: ...er Conditioner Flow Diagrams A Downflow 1 Service Position 2 Backwash Position 3 Brine Slow Rinse Position 4 Rapid Rinse Position 5 Brine Tank Refill Position W110 LXT Downflow Softeners and SXT Filters 26 ...

Страница 27: ...w 1 Service Position 2 Backwash Position 3 Brine Slow Rinse Position Water Conditioner Flow Diagrams continued 4 Rapid Rinse Position 5 Brine Tank Refill Position 27 W110 LXT Downflow Softeners and SXT Filters ...

Страница 28: ...Sense Error An undesired optical sensor state change occurred Non critical error Extra optical sensor pulse detected Press any button to clear the error Press extra cycle button to advance motor to clear error 2 Regen Failure The system has not regenerated in 30 days Perform a Manual Regeneration to reset the error code If the system is metered verify that it is measuring flow by running service w...

Страница 29: ...t regenerated for more than 99 days or 7 days if the Control Type has been set to Day of Week Perform a Manual Regeneration to reset the error code If the system is metered verify that it is measuring flow by running service water and watching for the flow indicator on the display If the unit does not measure flow verify that the meter cable is connected properly and that the meter is functioning ...

Страница 30: ..._________ 2 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Re generation B System 4 Time Clock 3 Timer Program Settings A Backwash _______________________________Minutes B Brine and Slow Rinse ______________________Minutes C Rapid Rinse ______________________________Minutes D Brine Tank Refill __________________________Minutes E Pause Time ______________________________Minutes F Second...

Страница 31: ...NOTES 31 W110 LXT Downflow Softeners and SXT Filters ...

Страница 32: ...IFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT SHALL WATTS BE LIABLE IN CONTRACT TORT STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY FOR INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR PROPERTY DAMAGE REGARDLESS ...

Отзывы: