Master Programming Mode Chart
SXT
Before entering Master Programming, please contact your local
professional water dealer .
Master Programming Options
Abbreviation
Parameter
Option Abbreviation
Options
DF
Display Format
GAL
Gallons
Ltr
Liters
VT
Valve Type
5800
W110 Control Valve
RF
Regenerant Flow
dF1b
Standard Downflow Single Backwash
dF2b
Standard Downflow Double Backwash
Fltr
Filter
AIO
Air Injection Oxidizer
dFFF
Downflow Fill First
UFbd
Upflow Brine First
UFFF
Upflow Fill First
Othr
Other
CT
Control Type
Fd
Meter (Flow) Delayed
FI
Meter (Flow) Immediate
tc
Time Clock
dAY
Day of Week
C
Unit Capacity
Unit Capacity (Grains)
H
Feedwater Hardness
Hardness of Inlet Water (Grains)
RS
Reserve Selection
SF
Percentage Safety Factor
rc
Fixed Reserve Capacity
SF
Safety Factor
Percentage of the system capacity to be used as a reserve
RC
Fixed Reserve Capacity
Fixed volume to be used as reserve
DO
Day Override
The system's day override setting
RT
Regen Time
The time of day the system will regenerate
BW, BD, RR, BF
Regen Cycle Step Times
The time duration for each regeneration step. Adjustable from OFF and 0-199
minutes.
NOTE: If "Othr" is chosen under "Valve Type", then C1, C2, ...,
C20 will be displayed along with available cycle steps
RR, BD, SR, BW, RF, SP. LC denotes the Last Cycle.
D1, D2, D3, D4, D5,
D6, & D7
Day of Week Settings
Regeneration setting (On or Off) for each day of the week on day-of-week systems.
CD
Current Day
The Current day of the week
FM
Flow Meter Type
P0.7
3/4" Paddle Wheel Meter
t0.7
3/4" Turbine Meter
P1.0
1" Paddle Wheel Meter
t1.0
1" Turbine Meter
P1.5
1.5" Paddle Wheel Meter
t1.5
1.5" Turbine Meter
P2.0
2" Paddle Wheel Meter
Gen
Generic or Other non-Fleck Meter
K
Meter Pulse Setting
Meter pulses per gallon for generic/other flow meter
Some items may not be shown depending on timer
configuration. The timer will discard any changes and exit
Master Programming Mode if any button is not pressed for 5
minutes.
CAUTION
!
W110 LXT Downflow Softeners and SXT Filters
14