background image

9

Feed Water Valve Installation 

Caution: 

Water supply line to the system must be from the cold water supply line only.    

Hot water will severely damage your system.  

Do not use Teflon tape with the Adapt-a-Valve. 

1)

 Turn off the cold water supply to the faucet by turning the angle stop valve completely off. 

2) 

Attach the adapt-a-valve as illustrated in the three photos above, choosing the configuration that fits your  plumbing.  

Drain Saddle Installation 

Use the ¼" Drain Saddle with non air-gap faucet and 3/8" with air-gap faucet. 

CAUTION

!

 

If you have a garbage disposal, do not install the drain saddle near it. Installation  of the drain 

saddle must be either above the garbage disposal, or if a second sink drain is available, install 

it above the cross bar on the second drain. Installation of the drain saddle near a garbage 

disposal may cause the drain line to plug.   

1) 

 Gather the pieces of the drain saddle 

1 Black compression nut  

  

1 Semicircle bracket with opening 

2 Screws  

  

  

  

1 Foam gasket 

2 Nuts for screws  

  

  

1 Semicircle bracket  

2)  

The small square black foam gasket with a circle cut out of the middle must be applied to 

the inside of the drain saddle. Remove sticky tape backing and stick to the drain saddle as 

shown.  

3)

  The drain saddle must be mounted at least 1 ½" above the nut of the P-trap or cross bar  

from the garbage disposal to insure proper drainage. Assemble the drain saddle around the 

drain pipe at the best available location. Using Phillips screw driver tighten screws evenly and 

securely on both sides of the drain saddle. Keep the plastic compression nut off at this time.  

Do not over tighten the screws. It may crack the drain saddle. 

CAUTION

!

WARNING

!

Configuration for 3/8" 
(with brass fittings)  
*Insert white washer

Hot  

Cold 

Supply  

Supply

Configuration for 1/2"  
(without brass fittings)

Содержание W-415-NF

Страница 1: ...unsafe or of unknown quality without adequate disinfection before or after the system WARNING If you are unsure about installing your WATTS water filter contact a WATTS representative or consult a pr...

Страница 2: ...rain saddle clamp 3 8 feed water valve faucet assembly 4 Manual Recommended Tools Lists Variable speed drill 1 8 and 1 4 drill bits 7 16 drill bit 1 2 and 9 16 open end wrenches or adjustable Phillips...

Страница 3: ...on filter Auto shut off valve Operating pressure 40 100 PSI Operating temperature 40 100 F Please contact your local dealer at Replacement Parts WATTS ITEM DESCRIPTIONS SERVICE LIFE FPMB5 978 Sediment...

Страница 4: ...bon filter Auto shut off valve Operating pressure 40 100 PSI Operating temperature 40 100 F Please contact your local dealer at Replacement Parts WATTS ITEM DESCRIPTIONS SERVICE LIFE FPMB5 978 Sedimen...

Страница 5: ...age TFC membrane 50GPD 60 PSI 5th stage Inline carbon filter Auto shut off valve Operating pressure 40 100 PSI Operating temperature 40 100 F WATTS ITEM DESCRIPTIONS SERVICE LIFE FPMB5 978 Sediment fi...

Страница 6: ...sition while the o ring provides a permanent leak proof seal 4 PULL TO CHECK SECURE Pull on the tube to check that it is secure It is a good practice to test the system prior to leaving site and or be...

Страница 7: ...keep the drill bit cool If drill bit gets hot it may cause the porcelain to crack or chip 3 Using a 1 hole saw proceed to drill the large hole Keep drill speed on the slowest speed and use lubricating...

Страница 8: ...to the 3 8 quick connect elbow on the polishing filter With Non Air Gap faucets this will be the only tube connected to the RO faucet Air Gap Faucet Follow the drinking feed tube connection instruc ti...

Страница 9: ...n saddle near a garbage disposal may cause the drain line to plug 1 Gather the pieces of the drain saddle 1 Black compression nut 1 Semicircle bracket with opening 2 Screws 1 Foam gasket 2 Nuts for sc...

Страница 10: ...all valve off TOP VIEW OF TANK BALL VALVE PPSV501222W OFF POSITION ON POSITION STEP 4 Mounting the Drain Clamp The drain saddle and part number to SC500B14 will fit most stan dard drain pipe It should...

Страница 11: ...e local water temperature and water pressure NOTE During the fill period you may hear water trickling due to the Reverse Osmosis Process 4 After the Tank has filled open the RO Faucet to flush the tan...

Страница 12: ...ty b Fill the tank sanitizer feeder with the recommended disinfectant dosage and connect the feeder to the water supply and RO storage tank c Turn on water supply and force water and disinfectant solu...

Страница 13: ...pen the housing you may try unplugging the fitting between red tubing and the system in order to reduce the air and water pressure inside the housing 3 Filter and membrane change procedures a Shut off...

Страница 14: ...te conversion of trivalent arsenic to pentavalent arsenic Please see the Arsenic Facts section of the Performance Data Sheet for further information Depending on water chemistry water temperature and...

Страница 15: ...s of arsenic are potentially hazardous to your health trivalent arsenic is considered more harmful than pentavalent arsenic RO systems are very effective at removing pentavalent arsenic A free chlorin...

Страница 16: ...in storage tank is low Normally it takes 2 3 hours to fill tank Low water pressure and or temperatures can reduce production rate Add pressure to storage tank The pressure should be 8 10 psi when the...

Страница 17: ...m 4 The pH of the water must not be lower than 2 or higher than 11 5 The incoming water pressure must be between 40 and 100 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FU...

Отзывы: