Feed Water Valve Installation
Caution:
Water supply line to the system must be from the cold water supply line only.
Hot water will severely damage your system.
Do not use Teflon tape with the Adapt-a-Valve.
1)
Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
2)
Attach the adapt-a-valve as illustrated in the three photos above, choosing the configuration that fits your plumbing.
Drain Saddle Installation
Use the ¼" Drain Saddle with non air-gap faucet and 3/8" with air-gap faucet.
CAUTION
!
If you have a garbage disposal, do not install the drain saddle near it. Installation of the drain
saddle must be either above the garbage disposal, or if a second sink drain is available, install
it above the cross bar on the second drain. Installation of the drain saddle near a garbage
disposal may cause the drain line to plug.
1)
Gather the pieces of the drain saddle
1 Black compression nut
1 Semicircle bracket with opening
2 Screws
1 Foam gasket
2 Nuts for screws
1 Semicircle bracket
2)
The small square black foam gasket with a circle cut out of the middle must be applied to
the inside of the drain saddle. Remove sticky tape backing and stick to the drain saddle as
shown.
3)
The drain saddle must be mounted at least 1 ½" above the nut of the P-trap or cross bar
from the garbage disposal to insure proper drainage. Assemble the drain saddle around the
drain pipe at the best available location. Using Phillips screw driver tighten screws evenly and
securely on both sides of the drain saddle. Keep the plastic compression nut off at this time.
Do not over tighten the screws. It may crack the drain saddle.
CAUTION
!
WARNING
!
Configuration for 3/8"
(with brass fittings)
*Insert white washer
Hot
Cold
Supply
Supply
Configuration for 1/2"
(without brass fittings)