8. InSTalleR PaRaMeTeR DeScRIPTIon
To access to these installer parameters, installer has to go to user parameter number 15.
After, he presses and holds validation key during 5 seconds:
selecting temperature sensor used for the regulation:
-
aIR
: regulation with internal sensor
-
amb
: regulation with external sensor
-
flR
: regulation on floor sensor (external sensor of remote,
only when thermostat is connected to master) or embedded
sensor on receiver
-
fll
: regulation with floor sensor and air sensor
Factory setting value:
air
Other values:
amb / fll / flR
lower limit of floor temperature (Fl.l)
This value is used when parameter 20 is FLL
Factory setting value:
“no”
: not activated
Other values:
5°c
to
“fl.H”
high limitation of floor temperature (Fl.h)
This value is used when parameter 20 is set on “floor limit”
FLL.
Factory setting value:
“no”
: not activated
Other values:
“fl.lo”
to
40°c
Displaying of
measured temperature by floor sensor
connected to receiver
(only with specific bidirectional
system)
If “Err” is displayed, thermostat isn’t associated to a received
with floor sensor or this sensor is damaged.
Displaying of
measured temperature by internal sensor:
If “Err” is displayed, internal sensor is damaged.
Displaying of
measured temperature by external sensor:
➤
FlOOR
temperature /
AMBiEnT
temperature
If “Err” is displayed, external/ambient sensor isn’t connected
or damaged.
Accessing to installer parameters
holding
button
holding
button
releasing
button
Installer
parameters