10
BT-D03-MOI-FR-W-EN-06-19
English
English
En
En
6.2 Reversible mode
Reversible menu access is only pos-
sible on two conditions:
- thermostat isn’t associated to a touch
screen or 6Z master
- « reversible menu » is activated in the
user parameter menu.
Enter user parameter 08, use keys
and
, to select operating mode of the
thermostat:
-
Hot
: Heating regulation mode
-
cld
: Cooling regulation mode
-
rev
: activation of reversible mode in
menu
-
aut
: automatic Heat/Cool mode.
Pressing key confirms the selection
and switches to comfort mode. A user
inactivity of some seconds confirms cur-
rent selection and returns to old selected
mode.
By pressing key, temperature set point
value is validated.
6.3 opened windows detection
Enter user parameter 07.
When activated and a detection is run-
ning, the icon
will appear and blink
on the screen!; This function is done by
measuring and recording the temperature
evolution.
When an opened window is detected, the
thermostat applies to heating system anti-
freeze temperature set point. User can
restart heating system, and stops window
detection by pressing on a key.
6.4 Reset
By holding the button on the back of ther-
mostat, user can:
- Unlock pin code
- Go directly to pairing menu (5 seconds)
- Reset thermostat with user parameter
value equal to factory setting. (10 sec-
onds).
6.5 Keyboard locking
Wake-up the thermostat (lighted back-
light),
Press and hold and keys simultane-
ously.
Once locking is activated, logo
appears
on the LCD screen:
5/10 Seconds