background image

6.

  Pull the power supply wiring into this box, leaving about 6 inches of wire.

7.

  Pull the floor sensor wire and the power lead wires from your floor warming 

system up the wall, into this box.  Refer to your floor warming system 
installation instructions for placement of the floor sensor tip into the floor area.

8.

  Mount the electrical box.

Owner’s Manual

Your new SunStat Dial thermostat

 is designed to control the voltage to 

either a 120VAC or 240VAC resistive floor warming system.

Please follow this manual for complete installation and operation instructions.  
If you have any questions or comments, try calling Technical Support at  
1-800-276-2419.

Make sure you are qualified and are familiar with house wiring.  This is a 
line voltage device that could cause serious injury or damage if improperly 
installed.

SunStat Dial

Dial Thermostat

Model 500710

1.  Preparation

1.

  Unpack your thermostat and make sure everything is in good condition:

Thermostat

• 

Floor sensor

• 

Small screwdriver

• 

Mounting screws

• 

Wire nuts for wiring connections

• 

If any parts are missing or damaged, contact the store where you purchased 
this thermostat.  Do not install a damaged part.

2.

  Gather the following tools and supplies:

  •Phillips screwdriver, hole saw
  •Wire strippers, “fish tape”, other electrical tools
  •Electrical box for thermostat:
 

a.

 If you are connecting to power leads from only 1 or 2 floor warming 

 

systems, you may use a single-gang, 3

1

2

 inch deep box.

 

b.

 If you are connecting to power leads from 2 or 3 floor warming systems, 

 

use a 4x4x2

1

inch or deeper box (not a 2-gang box) when your wall studs 

 

are still exposed. Install a single-gang “mud-ring” cover on the box before 

 

installing drywall materials.

 

c.

 For more than 3 floor warming systems or other layouts, you may need 

 

to install a junction box. See the installation instructions for your floor 

 

warming system for more information.

 

ALWAYS

:  Wire all circuits as Class 1, Electric Light and Power Circuits.

 

ALWAYS

:  Wire all circuits with insulation rated 600V minimum.

 

ALWAYS

:  Mount this control only to a grounded metallic box or a 

 nonmetallic 

box.

 

ALWAYS

:  Use power supply wires suitable for at least 90°C.

 
 

CAUTION

:  High voltage – disconnect power supply before servicing.

2.  Installation

Remove the Thermostat Face

1.

  Remove the thermostat Front Module 

from the Power Module by opening the door 
and loosening the screw.

2.

  Pull outward near the bottom on the 

Front Module and lift off.

Prepare the Wiring

1.

  Find a location for your thermostat.  It 

is suitable for indoor use only, on insulated 
or uninsulated walls.  Locate it about 4

1

2

 feet to 5 feet above the floor on an 

inside wall.  Avoid placing it near other heat sources such as hot-water piping, 
heat duct, wall-mount lighting, and direct sunlight to help prevent adversely 
affecting the thermostat.

2.

  Turn off the power to the floor warming system at the main circuit panel 

before doing any electrical work.

3.

  A qualified electrician should run a dedicated circuit from the main circuit 

panel to the thermostat location.

4.

  If a dedicated circuit is not possible, you may tap from another circuit in the 

room.  Make sure there is enough load capacity (amps) to handle the addition 
of your floor warming system, and that it is NOT wired in series with any other 
device, including other GFCIs.

5.

  The circuit breaker in the main circuit panel should be 15 amps maximum 

for a floor warming system totaling 12 amps or less.  For larger systems up to 
15 amps, use a 20 amp maximum circuit breaker. Never exceed 15 amps on 
this thermostat.

power 
module

front 
module

5

sensor

Connect Wires

1.

  Match and connect the two 

wires marked “LINE1” and 
“LINE2” to the power supply wires 
using the wire nuts provided.

2.

  Gently tug on the wires to 

make sure they are secure, 
otherwise a wire could loosen 
and cause failure.

3.

  Overwrap the wire nuts with 

electrical tape to better secure 
them to the wires.

4.

  Match and connect the two 

wires marked “LOAD1” and 
“LOAD2” to the floor warming 
system lead wires and secure 
these wires the same way.

5.

  Connect the house ground 

wire to the green lead wire(s) of 
your floor warming system.

6.

  Insert the ends of the floor 

sensor wire into the “SENSOR” 
terminals (1 and 2) and tighten 
the screws.  There is no polarity, 
so it does not matter which wire 
end goes into which terminal.

CAUTION: 

 Before continuing, 

make sure your power supply 
voltage matches the voltage 
rating of your floor warming 
system.  
Connecting 240V to a 120V floor warming system will cause overheating and 
damage to the system and may damage the control, other wiring, floor cover-
ings, etc.

SunStat Relays

1.

  If you want to use your thermostat to drive a SunStat Relay(s) (ask 

your dealer about this convenient way to control larger systems with one 
thermostat), first read and follow the instructions for the SunStat Relay 
thoroughly.

2.

  Pull 2-conductor wire, size 18- to 24-gage, through the wall from the 

SunStat Relay, into this electrical box.

3.

  Connect the wire ends into the “RELOUT” terminals (3 and 4) and tighten 

the screws (no polarity).

 

Mount the Thermostat

1.

  Carefully fold and press the wires 

back into the electrical box.  Do not use 
the thermostat to push them in, as this 
may cause connections to loosen and 
possible failure.

2.

  Secure the thermostat Power Module 

into the box with the mounting screws 
provided.

3.

  Carefully snap the Front Module onto 

the Power Module.

4.

  Tighten the screw.

5.

  Switch on the power at the main 

circuit panel.

NOTE to contractors:

 

After installing 

the thermostat, be sure to:

 

a.

 

Switch on the thermostat and turn up the temperature to make sure it 

 

is heating for a few minutes (section 3)

 

b.

 

Test the GFCI (section 3).

1-4

from 
power 
supply

to
floor 
warming 
system