manualshive.com logo in svg
background image

3

Permeate Pump Installation  

with the Standard System 

Parts Needed

(1) Permeate Pump with mounting clip
(1) 48" long, 

1

4

" Blue tube

NOTE: When mounting the Permeate Pump, make sure the 

outlet ports of the Permeate Pump are above the inlet ports in 

order to allow entrapped air to escape 

1.     Turn off the incoming water to the reverse osmosis unit. Lift the 

handle on the reverse osmosis drinking water faucet to drain the 

water from the system and storage tank . 

Note: If tank is equipped with a ball valve, close valve to  

preserve the tank water.

2.     Before installing the Permeate Pump, remove the blue tube in-

serts from the ports . Refer to the diagram on Page 2 for instruc-

tions for disconnecting from a Quick-Connect fitting .

3 .     Cut the blue tube between the shutoff valve and the membrane 

housing . Then insert the end from the reverse osmosis mem-

brane into the Permeate Pump “PERMEATE IN” port .

4 .     Insert the tube from the shutoff valve into the Permeate Pump 

“PERMEATE OUT” port .  Use the additional blue tubing if extra 

length is needed .

5 .     Cut  the 

1

4

" waste line from the membrane (after the flow restric-

tor) and insert the tube from the membrane into the Permeate 

Pump “BRINE IN” port (Make sure the flow restrictor is located 

between the Permeate Pump and the membrane).

6 .     Insert  the 

1

4

" red tube from the faucet air gap inlet into the  

Permeate Pump “BRINE OUT” port.

7 .     Make sure your installation matches the diagram shown in  

Figure 1.

8 .     Turn on the water supply .  Check for leaks periodically for the 

next 24-48 hours as the system fills and again after it shuts off 

when the tank is full .

Figure 1:  Standard System after installation of Permeate Pump

 Installation Steps

3

8

" BLACK TUBE DRAIN

RED TUBE

BLUE TUBE

BLUE TUBE

GREEN TUBE

GREEN TUBE

RED TUBE

Содержание PWPERMKIT

Страница 1: ...with the Manifold System 4 5 Permeate Pump Installation with the KWIK CHANGE RO 6 7 Limited Warranty 8 PWPERMKIT PURE WATER Important Please read the entire manual before proceeding with the installat...

Страница 2: ...indicate how far the tube should be inserted The unique Watts Quick Connect locking system holds the tube firmly in place without deforming it or restrict ing flow Cut the tube square It is essential...

Страница 3: ...the membrane housing Then insert the end from the reverse osmosis mem brane into the Permeate Pump PERMEATE IN port 4 Insert the tube from the shutoff valve into the Permeate Pump PERMEATE OUT port U...

Страница 4: ...disconnecting from a Quick Connect fitting 3 Remove the 3 8 Blue tube from the manifold TANK port and insert the 3 8 Plug 4 Locate the 3 8 Blue tube from the manifold FAUCET port and cut approximatel...

Страница 5: ...5 Figure 2 Manifold System after installation of Permeate Pump RED FLOW RESTRICTOR BLUE GREEN BLUE BLUE BLUE BLUE BLUE RED RED RED 3 8 BLACK TUBE DRAIN...

Страница 6: ...4 Unplug and remove the blue tube located between the shutoff valve s OUT port and the elbow above the green filter Insert a 1 4 plug into the elbow 5 Use the additional blue tube and insert one end i...

Страница 7: ...7 Figure 3 KWIK CHANGE RO after installation of Permeate Pump RED TUBE RED TUBE BLUE TUBE BLUE TUBE GREEN TUBE BLUE TUBE...

Страница 8: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PER...

Отзывы: