Permeate Pump Installation  

with the Manifold System 

Parts Needed

(1) Permeate Pump with mounting clip
(2) Quick-Connect Reducer Union
(2) 3" long, 

1

4

" Blue tubes

(1) 48" long, 

1

4

" Blue tube

(1) 

3

8

" Quick-Connect Union Tee

(1) 

3

8

" Plug Insert

NOTE:  The Permeate Pump is equipped with ¼" Quick-Connect 

push-to-connect fittings. The pump can be used in RO systems 

with 

3

8

" tubing by inserting a short piece of 

1

4

" tubing into the 

port on the Permeate Pump and attaching a Quick-Connect 

Reducer Union to the tubing. Also, when mounting the Perme-

ate Pump, make sure the outlet ports of the Permeate Pump are 

above the inlet ports in order to allow entrapped air to escape 

1.     Turn off the incoming water to the reverse osmosis unit. Lift the 

handle on the reverse osmosis drinking water faucet to drain the 

water from the system and storage tank .  

Note: If tank is equipped with a ball valve, close valve to  

preserve the tank water.

2.     Before installing the Permeate Pump, remove the blue tube in-

serts from the ports . Refer to the diagram on Page 2 for instruc-

tions for disconnecting from a Quick-Connect fitting .

3 .     Remove  the 

3

8

" Blue tube from the manifold “TANK” port and 

insert the 

3

8

" Plug

4 .     Locate  the 

3

8

" Blue tube from the manifold “FAUCET” port and 

cut approximately 24" from the manifold and re-route into the 

Permeate Pump “PERMEATE IN” port using  a Reducer Union 

and a 3" long, 

1

4

" Blue tube.

5 .     Insert  the 

3

8

" Blue tube from the faucet into the Permeate Pump 

“PERMEATE OUT” port using a Reducer Union and a 3" long, 

1

4

" Blue tube.

6 .     Locate  the 

3

8

" Blue tube between the faucet and Permeate 

Pump, and then cut and insert the 

3

8

" Union Tee.

7 .     Insert  the 

3

8

" Blue tube leading to the tank into the open port of 

the 

3

8

" Union Tee

8 .     Locate  the 

1

4

" Red tube between the manifold “DRAIN” port 

and the faucet air gap inlet and then cut the tube 24" from the 

manifold (Making sure to leave the flow restrictor plugged into 

the manifold)  Insert the red tube from the manifold into the Per-

meate Pump “BRINE IN” port and the red tube from the faucet 

into the Permeate Pump “BRINE OUT” port.

9 .     Make sure your installation matches the diagram shown in  

Figure 2

10.    Turn on the water supply. Check for leaks periodically for the 

next 24-48 hours as the system fills and again after it shuts off 

when the tank is full .

 Installation Steps

Содержание PWPERMKIT

Страница 1: ...with the Manifold System 4 5 Permeate Pump Installation with the KWIK CHANGE RO 6 7 Limited Warranty 8 PWPERMKIT PURE WATER Important Please read the entire manual before proceeding with the installat...

Страница 2: ...indicate how far the tube should be inserted The unique Watts Quick Connect locking system holds the tube firmly in place without deforming it or restrict ing flow Cut the tube square It is essential...

Страница 3: ...the membrane housing Then insert the end from the reverse osmosis mem brane into the Permeate Pump PERMEATE IN port 4 Insert the tube from the shutoff valve into the Permeate Pump PERMEATE OUT port U...

Страница 4: ...disconnecting from a Quick Connect fitting 3 Remove the 3 8 Blue tube from the manifold TANK port and insert the 3 8 Plug 4 Locate the 3 8 Blue tube from the manifold FAUCET port and cut approximatel...

Страница 5: ...5 Figure 2 Manifold System after installation of Permeate Pump RED FLOW RESTRICTOR BLUE GREEN BLUE BLUE BLUE BLUE BLUE RED RED RED 3 8 BLACK TUBE DRAIN...

Страница 6: ...4 Unplug and remove the blue tube located between the shutoff valve s OUT port and the elbow above the green filter Insert a 1 4 plug into the elbow 5 Use the additional blue tube and insert one end i...

Страница 7: ...7 Figure 3 KWIK CHANGE RO after installation of Permeate Pump RED TUBE RED TUBE BLUE TUBE BLUE TUBE GREEN TUBE BLUE TUBE...

Страница 8: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PER...

Отзывы: