Operation & Maintenance Manual
AquaSolve
®
IOM-M8408_M8410-COM_EN
Page 6 of 8
Technical Support
• (800) 433-5654 • Mon-Fri, 8 am - 5 pm EST
By-Pass Valve
Fill in install date and rebed due date on product label located on
front of each tank as reminder to replace AquaSolve media every
3 years. The system is now ready for service.
NOTICE
5. Turn the water back on to the AquaSolve system.
Slowly open the supply valve (user supplied) to
the AquaSolve system. Slowly place AquaSolve
By-Pass Valve into Service position (see image
above for reference). Allow the tank to fill with
water. Close the supply valve when a steady stream
of water comes out of the outlet port. If the outlet is
flowing into a bucket, water could splash on nearby
objects. If this threatens the safety, value, structure,
or appearance of these objects, protect/remove
them or use the outlet hose to drain option.
6. Connect the outlet of the AquaSolve system to the
cold water supply to the building.
7. Open the supply valve to the AquaSolve system.
8. Open hot and cold faucets downstream from
the AquaSolve system to relieve any air from the
plumbing system. Then close the faucets.
9. Check for leaks. Repair as needed.
Installation and Start-Up
1. Turn off the main water supply to the AquaSolve
System and open an inside faucet to relieve any
pressure within the plumbing system. Close the
inside faucet once pressure is released.
2. Place the system in the desired location. Make sure
that the location is level and sturdy enough to sup-
port the weight of the wetted system.
3. Connect the cold water supply to the inlet of the
AquaSolve system.
NOTE: The AquaSolve system operates in
the UP-FLOW mode which is opposite of a
conventional softener.
4. Place a bucket under the outlet port or run a line
from the outlet port to a drain.