background image

Operation & Maintenance Manual 

AquaSolve

®

IOM-M8408_M8410-COM_EN

Page 6 of 8

Technical Support

  •  (800) 433-5654  •  Mon-Fri, 8 am - 5 pm EST

By-Pass Valve

Fill in install date and rebed due date on product label located on 
front of each tank as reminder to replace AquaSolve media every 
3 years. The system is now ready for service.

NOTICE

5.  Turn the water back on to the AquaSolve system. 

Slowly open the supply valve (user supplied) to 
the AquaSolve system. Slowly place AquaSolve 
By-Pass Valve into Service position (see image 
above for reference). Allow the tank to fill with 
water. Close the supply valve when a steady stream 
of water comes out of the outlet port. If the outlet is 
flowing into a bucket, water could splash on nearby 
objects. If this threatens the safety, value, structure, 
or appearance of these objects, protect/remove 
them or use the outlet hose to drain option.

6.  Connect the outlet of the AquaSolve system to the 

cold water supply to the building.

7.  Open the supply valve to the AquaSolve system.
8.  Open hot and cold faucets downstream from 

the AquaSolve system to relieve any air from the 
plumbing system. Then close the faucets.

9.  Check for leaks. Repair as needed.

Installation and Start-Up 
 

 

1.  Turn off the main water supply to the AquaSolve 

System and open an inside faucet to relieve any 
pressure within the plumbing system. Close the 
inside faucet once pressure is released.

2.  Place the system in the desired location. Make sure 

that the location is level and sturdy enough to sup-
port the weight of the wetted system.

3.  Connect the cold water supply to the inlet of the 

AquaSolve system.

 

NOTE: The AquaSolve system operates in  
the UP-FLOW mode which is opposite of a  
conventional softener.

4.  Place a bucket under the outlet port or run a line 

from the outlet port to a drain.

Содержание PVI AquaSolve M8408-COM

Страница 1: ...5 9531 Toll Free 800 784 8326 PVI com Technical Support 800 433 5654 Mon Fri 8 am 5 pm EST Manufacturing ASME Commercial Water Heaters Since 1961 IOM M8408_M8410 COM_EN Important Read this Manual BEFO...

Страница 2: ...e require adjustments AquaSolve Benefits Chemical free scale prevention and protection converts hardness minerals to harmless inactive microscopic crystals making AquaSolve an effec tive alternative t...

Страница 3: ...uaSolve there are some unique requirements for using AquaSolve in conjunction with other forms of water treatment 1 AquaSolve must be the last stage in the treatment chain Do not install any filters a...

Страница 4: ...scaling While silica tends to have a less significant effect on scale formation than other miner als it can act as a binder that makes water spots and scale residue outside the plumbing system difficu...

Страница 5: ...o isolate the tank for servicing A full bypass should be installed so that the full service flow can be routed around the system as needed for servicing NOTICE Install Piping Connect the inlet and out...

Страница 6: ...f these objects protect remove them or use the outlet hose to drain option 6 Connect the outlet of the AquaSolve system to the cold water supply to the building 7 Open the supply valve to the AquaSolv...

Страница 7: ...ng the media You need to take it out in small bites If you let the whole pipe hose fill with media it will plug up You need to let slugs of water flush out the pipe as you go 11 When all the old media...

Страница 8: ...ring any part or parts to our satisfaction that prove defective within the warranty period stated above Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding...

Отзывы: