Specifications

AquaSolve scale prevention system shall be installed 
on the main water service pipe just after it enters the 
building, but after other whole building water safety 
devices (backflow preventers or pres-sure reducing 
valves), to effectively address water hardness con-
cerns. A system may also be installed further down-
stream to protect specific equipment or areas within 
a plumbing system. The system shall be plumbed 
with a bypass valve to allow isolation of tank(s) and 
to allow the bypass of untreated water in the event 
that service or media replacement be necessary. The 
installation area should be suitable in size for the 
tank(s) to be serviced without encumbrance and sit 
upright on a flat level surface.

The system must operate in an upflow manner and 
does not require additional water to backwash, flush, 
or regenerate once put into service. The system does 
not require any chemical additives and does not 
require electricity for operation.

Multi-tank systems shall be installed in parallel with 
PVC/CPVC manifold to meet peak flow rate require-
ments – see image below.

Spotting may occur on external plumbing surfaces.

 

AquaSolve media systems perform best in single pass pota-
ble water applications with NO additional chemical additives. 
Depending on hardness, soft scale spotting may occur. Soft scale 
spots in most cases can be easily wiped down with a damp cloth 
and will not form hard scale deposits. A Point of Use (POU) Water 
Softener should be used on mandatory spot-free applications (e.g. 
glass stemware, dishware).

NOTICE

Using AquaSolve with other water treatment equipment.

Due to the unique properties of AquaSolve, there are some unique 
requirements for using AquaSolve in conjunction with other forms 
of water treatment:

1. AquaSolve must be the last stage in the treatment chain. Do 

not install any filters after AquaSolve or before any devices for 
which scale prevention is required. POU filters, e.g. carbon, 
RO or Ultraviolet (UV) are exempt from this requirement.

2. Do not apply phosphate or any other antiscalant before or 

after AquaSolve.

3. The addition of soaps, chemicals, or cleaners, before or after 

AquaSolve treatment, may reverse its anti-scale treatment 
effects and/or create water with a heavy residue or spotting 
potential. Any adverse conditions caused by the addition of 
soaps, chemicals, or cleaners are the sole responsibility of the 
end user.

4. AquaSolve is not a water softener and does not softener the 

water - water treatment chemistry (e.g. antiscalants, seque 
trants, soaps, chemicals or cleaners etc.) will most likely have 
to be changed to be compatible with AquaSolve treated water. 
Laundry and ware-washing chemistry will likewise require 
adjustments.

WARNING

•  Not for use on closed loop systems.
•  Do not let the system freeze. Damage to the tank may result.
•  System must be operated in a vertical position. Do not lay 

it down during operation. The system may be placed in any 
position

•  for shipping and installation but must be operated in the verti-

cal position.

•  Place the system on a smooth, level surface. Because the sys-

tem operates in an upflow, fluidized bed mode, having a level 
surface is more important than with a softener or media filter.

•  A bypass valve should be installed on every system to facili-

tate installation and service.

•  Observe all local plumbing and building codes when installing 

the system.

CAUTION

Standards

Independent scientific testing has confirmed 
Template Assisted Crystallization (TAC) technology 
provides scale reduction of over 95+%. Testing was 
conducted under protocol based on DVGW W512 
test to access control of scale formation.

Содержание PVI AquaSolve M8408-COM

Страница 1: ...5 9531 Toll Free 800 784 8326 PVI com Technical Support 800 433 5654 Mon Fri 8 am 5 pm EST Manufacturing ASME Commercial Water Heaters Since 1961 IOM M8408_M8410 COM_EN Important Read this Manual BEFO...

Страница 2: ...e require adjustments AquaSolve Benefits Chemical free scale prevention and protection converts hardness minerals to harmless inactive microscopic crystals making AquaSolve an effec tive alternative t...

Страница 3: ...uaSolve there are some unique requirements for using AquaSolve in conjunction with other forms of water treatment 1 AquaSolve must be the last stage in the treatment chain Do not install any filters a...

Страница 4: ...scaling While silica tends to have a less significant effect on scale formation than other miner als it can act as a binder that makes water spots and scale residue outside the plumbing system difficu...

Страница 5: ...o isolate the tank for servicing A full bypass should be installed so that the full service flow can be routed around the system as needed for servicing NOTICE Install Piping Connect the inlet and out...

Страница 6: ...f these objects protect remove them or use the outlet hose to drain option 6 Connect the outlet of the AquaSolve system to the cold water supply to the building 7 Open the supply valve to the AquaSolv...

Страница 7: ...ng the media You need to take it out in small bites If you let the whole pipe hose fill with media it will plug up You need to let slugs of water flush out the pipe as you go 11 When all the old media...

Страница 8: ...ring any part or parts to our satisfaction that prove defective within the warranty period stated above Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding...

Отзывы: