background image

9

Downloading Wirelessly

Fusion data from an 

RF-3000LE Bluetooth

®

 Electrofusion Processor

 is downloaded wirelessly 

through the EF Utilities app. Once data has been downloaded, it can be viewed at any time with a 

smart phone, tablet, or computer.

To download fusion data from the processor to the EF Utilities app, perform the following steps:

 

1.  Turn ON the processor and allow it to proceed through the INTERNAL SELF TEST until it  

 

  reaches the CONNECT LEADS screen.

 

2.  Open the EF Utilities app on your smart phone or tablet and select, "Connect to EF Machine."

 

3.  Follow the download instructions in the app.

All progress indications and user feedback are communicated through the EF Utilities app which is 

available on iOS and Android app stores. To set up an account and register your EF processor(s), 

contact EF Technologies.

POWER SOURCES

When installing electrofusion fittings in field applications, it is necessary to have a reliable source of 

AC power for the processor. This AC power source should:

 

•  be well maintained and subjected to a periodic maintenance schedule.

 

•  provide output voltage within the specified operating range.

 

•  contain a matching outlet, which is required to connect with the plug equipped on the          

   processor.

Utility Power

Utility power is a reliable and ideal power source for the 

Rionfuser™ Electrofusion Processor

However, it is not practical to gain access to this kind of power source in field applications. When 

fusing with utility power, a dedicated connection to the service panel is recommended because the 

potential amperage draw is very high.

Generators

Fuel powered generators are also a good source of electrical power for the 

Rionfuser™ Electrofu-

sion Processor

. Always make a note of the minimum fitting power requirements. Additional power 

capacity is recommended for intangibles (i.e. powering other accessories, wear & tear, etc.). Before 

starting a fusion, it is important to make sure:

 

•  the generator has enough fuel to complete the electrofusion cycle.

 

•  the auto-throttle is disengaged (in anticipation of immediate power draw).

Inverters

Inverters are an acceptable AC power source for the 

Riofuser™ Electrofusion Processor

, though 

some produce output waveforms that are troublesome with specific fittings. We recommend perform-

ing compatibility tests using the lightest and heaviest anticipated loads before approving an inverter 

system. Feel free to contact us to discuss issues regarding the use of inverters.

Power Specifications

Extension Cords

Because electrofusion fittings produce a high amperage draw, the use of an extension cord is not 

encouraged. In the event such usage is necessary, the following lengths and wire gauges are recom-

mended:

Extension cords should not be used when fusing multiple fittings at the same time.

Cord Length

Wire Gauge

Less than 25 feet

12/3

Less than 50 feet

10/3

Less than 100 feet

8.3

Supply Voltage

97 VAC to 150 VAC

Supply Frequency

47 Hz to 70 Hz

Supply Waveform

Sine Wave or Square Wave

Output Current

20 Amps AC

Output Voltage

95 volts AC at 120 Volts Input

Содержание ORION RF-3000LE

Страница 1: ...erence WARNING Local building or plumbing codes may require modifications to the information provided You are required to consult the local building and plumbing codes prior to installation If the information provided here is not consistent with local building or plumbing codes the local codes should be followed This product must be installed by a licensed contractor in accordance with local codes...

Страница 2: ...date has passed This will not prevent the processor from performing fusions however the processor should be calibrated as soon as possible Service Contact Information Calibrating your Rionfuser Electrofusion Processor 1 Send the processor to a WATTS service center and let our technicians do it Call 302 451 1088 to make arrangements for service and to obtain an RMA number for the return Every effor...

Страница 3: ...eplaceable output cable ends User accessible fuse Emergency stop switch Can store fusion information for 1 000 fusions Specification Hermetically sealed joints conforming to ASTM F1290 Technique 1 are to be produced for the Orion chem ical piping system using the Orion Rionfuser machine model RF 3000LE an electrofusion processor designed to be used exclusively with Orion RFCF electrofusion couplin...

Страница 4: ...ipe ends Following the coupling insertion depth chart mark the coupling insertion depth from the end of the pipe fitting to insure that the coupling is properly positioned during the fusion cycle Then using 60 grit emery cloth abrade the marked ends of the pipe and fitting to remove the natural sheen of the plastic After abrading clean all joint surfaces thoroughly with isopropyl alcohol to remove...

Страница 5: ... the fusion assembly area If ambient temperature has dropped below 60F in the last 24 hrs we recommend the use of warming blankets to support wrap and protect the pipe during the fusion process With the Rionfuser unit connected to a dedicated power source and powered ON connect the lead cables to the coupling Step 5 Selecting Fitting Style The unit will now prompt the installer to SELECT FITTING S...

Страница 6: ...All other fusions should be performed using the STANDARD cycle which is selected by pressing the START button Step 8 Verifying Welding Parameters The screen will display VERIFY WELDING PARAMETERS and an audible beep will sound to indicate the fusion unit is ready to begin welding Verify the welding data displayed on the screen matches the joint being fused If the information is incorrect press the...

Страница 7: ...for the next joint To download completed fusion data please see our IOM OR RIONFUSE 2128 for instructions Successful weld completion screen NOTICE Do not stress newly fused joints until fully cooled to ambient typ ically 10 20 minutes depending on size Successful weld comple tion screen does not eliminate need for system leak testing POLYPROPYLENE RIONFUSE CF COUPLING Pipe Size Fusion Time Fusion ...

Страница 8: ...imilar to the following will be displayed as the download proceeds 5 After the download is complete the processor will return to the CONNECT FITTING screen You may now disconnect the USB flash drive from the USB Host Port to resume normal operation NOTE Only new fusions performed since the last download will be written to the drive The USB flash drive must be formatted using FAT or FAT32 with a se...

Страница 9: ... applications When fusing with utility power a dedicated connection to the service panel is recommended because the potential amperage draw is very high Generators Fuel powered generators are also a good source of electrical power for the Rionfuser Electrofu sion Processor Always make a note of the minimum fitting power requirements Additional power capacity is recommended for intangibles i e powe...

Страница 10: ...it will not fuse until it has been calibrated To schedule a calibration please see page 2 for instructions and contact information 90 DAY REMINDER Calibration Due On mm dd yyy PRESS START General Maintenance Changing the Fuse This section applies to the RF 3000LE Electrofusion Processor only The Rionfuser LT Elec trofusion Processor has no external fuse that can be changed Important Notes The fuse...

Страница 11: ...tunity to inspect any product alleged to be defective and the installation or use thereof NO WARRANTY IS INCLUDED AGAINST ANY EXPENSE FOR REMOVAL REINSTALLATION OR OTHER CONSEQUENTIAL DAMAGES ARISING FROM ANY DEFECT THE WARRANTIES SET OUT ABOVE ARE THE ONLY WARRANTIES MADE AND ARE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS...

Отзывы: