Installation

 

WARNING

!

Valve should be installed and adjusted by a licensed contrac-

tor in accordance with local codes and ordinances. Further, this 

valve should be installed in a location where it is accessible for 

cleaning, service or adjustment.
1.   Close both the hot and cold water shutoff valves upstream of 

the valve.

2.  Bleed pressure from the system.
3.  Route copper tubing to fit valve dimensions.
 

NOTICE

To prolong the life of the Series LF1170C-M2 valve, it is recom-

mended that it be trapped as shown: i.e. the hot water inlet to the 

LF1170C-M2 valve should be 8" – 12"   (200 – 305mm) below the 

hot water supply feed. 
Piping must be arranged as follows:

 

Valve Body Marking

 

H

 - Hot water supply inlet 

 

 

C

 - Cold water supply inlet 

 

M

 - Mixed water outlet

4.  Valve can be installed in any position. Note: the inlet hot sup-

ply is to be connected to the “H” side of the valve, the cold 

supply side to the “C” side and the mixed water outlet to the 

“M” side.

5.  Make sure union nuts are placed over tailpieces prior to  

soldering or threading to pipe.

6.  For valves with Quick-Connect tailpieces refer to “Quick- 

Connect Installation” instructions below.

 

NOTICE

To prevent damage to valve from excessive heat during soldering, 

remove unions and gaskets from valve body prior to soldering.

7.  After soldering, flush piping and install valve using filter washer 

on hot and cold water inlet and fiber washer on the mixed  

water outlet.

8.  Start-up: Open cold water supply, then hot water supply. 

Inspect for leaks.

IS-1170C-M2

Installation Instructions 

Series LF1170C-M2

Hot Water Temperature Control Valves

Size: 

1

2

", 

3

4

", 1" (15,  20, 25mm)

LF1170C-UT-M2

LF1170C-QC-M2  

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property  

damage, or damage to the equipment.
Keep this Manual for future reference.

You are required to consult the local building and plumbing 

codes prior to installation.  If the information in this manual 

is not consistent with local building or plumbing codes, 

the local codes should be followed. Inquire with governing 

authorities for additional local requirements.

WARNING

!

WARNING

!

Use caution when soldering. Protect yourself and others. FUMES 

AND GASES can be hazardous to your health.  HEAT RAYS (INFRARED 

RADIATION) from flame or hot metal can injure eyes. 

WARNING

!

Need for Periodic Inspection and Yearly Maintenance:   

Periodic inspection and yearly maintenance by a licensed 

contractor is required. Corrosive water conditions, tempera-

tures over 200°F, unauthorized adjustments or repair could 

render the valve ineffective for service intended. Regular 

checking and cleaning of the valve’s internal components and 

check stops helps assure maximum life and proper product 

function. Frequency of cleaning and inspection depends upon 

local water conditions.

FAILURE TO COMPLY WITH PROPER INSTALLATION AND 

MAINTENANCE INSTRUCTIONS COULD CONTRIBUTE TO THE VALVE 

FAILURE.
This Hot Water Master Tempering Valves cannot be used for temper-

ing water temperature at fixtures. Severe bodily injury (i.e., scalding 

or chilling) and/or death may result depending upon system water 

pressure changes and/or supply water temperature changes. ASSE 

standard 1016, 1069 or 1070 listed devices should be used at fix-

tures to prevent possible injury.

These Hot Water Tempering Valves are designed to be installed at or near 

the boiler or water heater. They are not designed to compensate for sys-

tem pressure fluctuations and should not be used where ASSE standard 

1016, 1069 or 1070 devices are required. These valves should never be 

used to provide “anti-scald” or “anti-chill” service.
The components of the system must be of materials with a construction 

capable of withstanding the high limit output temperatures of the water 

heating source.

WARNING

!

Содержание LF1170C-M2 Series

Страница 1: ...age to the equipment Keep this Manual for future reference You are required to consult the local building and plumbing codes prior to installation If the information in this manual is not consistent with local building or plumbing codes the local codes should be followed Inquire with governing authorities for additional local requirements WARNING WARNING Use caution when soldering Protect yourself...

Страница 2: ...e valve it is recommended the valve be trapped as shown Devices tested to ASSE Standard 1016 1069 or ASSE 1070 such as Watts LFUSG LFL111 or LFMMV should be used at fixture to prevent possible injury Domestic Hot Water Application Radiant Heat Application from Boiler Cold Radiant Return Mixed to Radiant to Boiler Watts Flow Check Watts Ball Valve TP Test Plug Watts Ball Valve RPV CV CVS Check Valv...

Страница 3: ... the piping system or install dielectric unions G All hot or cold water flows at hot fixture G 1 This problem will require consider able troubleshooting G 1 Verify that complete installation instructions were followed G 1a is valve properly trapped G 2 Check to see if thermostatic element has failed G 3 Check to see if temperature control on water heater is set at desired temperature G 4 Check to ...

Страница 4: ...AVERTISSEMENT Faites preuve de prudence lors du brasage Protégez vous et protégez les autres LES VAPEURS ET LES GAZ peuvent être dangereux pour votre santé LES RAYONS DE CHALEUR RAYONNEMENT INFRAROUGE issus des flammes ou du métal chaud peuvent blesser les yeux AVERTISSEMENT Nécessite une inspection périodique et un entretien annuel L inspection périodique et l entretien annuel doivent s effectuer...

Страница 5: ...comme illustré Utiliser les dispositifs testés selon le Standard 1016 1069 ou 1070 d ASSE comme les produits LFUSG LFL111 ou LFMMV de Watts au niveau du robinet pour éviter les blessures Utilisation domestique de l eau chaude Utilisation avec chaleur rayonnante en provenance de la chaudière Froid Rayonnant retour Mélangés vers Rayonnant vers la chaudière Vérifier le débit Watts Robinet à bille Wat...

Страница 6: ...ilicone approuvé par la FDA à la zone du piston de l élément est également bénéfique F 3 Relier le circuit de tuyauterie à la terre ou installer des joints union diélectriques G De l eau entièrement chaude ou entièrement froide coule du robinet d eau chaude G 1 Ce problème nécessitera dépannage considérable G 1 Vérifier que les instructions d installations complètes ont été respectées G 1a Le robi...

Отзывы: