SXT Diagnostics
Viewing Diagnostic Data
The SXT controller records and maintains diagnostic data to assist
with servicing and troubleshooting the water treatment system.
Abbreviation Parameter
Description
FR
Flow Rate
Displays the current outlet
flow rate.
PF
Peak Flow
Rate
Displays the highest flow rate
measured since last regeneration.
HR
Hours in
Service
Displays the total hours that the
unit has been in service since
last regeneration.
VU
Volume
Used
Displays the total volume of
water treated by the unit since
last regeneration.
RC
Reserve
Capacity
Displays the system’s reserve
capacity calculated from the
system capacity, feed water hard-
ness, and safety factor.
TV
Totalizer
Volume
Displays the total volume of
water used by the unit since last
installation or last reset.
SV
Software
Version
Displays the software version
installed on the controller.
NOTE: Some items may not be shown depending on
control configuration. The control will discard any
changes and exit the Diagnostics View if a button
is not pressed for 60 seconds.
Figure 25
Figure 26
Figure 27
Diagnostics View Steps
1. Press the Up and Extra Cycle buttons for five seconds while
in service.
2. Use this display to view the current Flow Rate. This option set-
ting is identified by “FR” in the upper left corner of the screen.
3. Press the Up button. Use this display to view the Peak Flow
Rate since the last regeneration cycle. This option setting is
identified by “PF” in the upper left corner of the screen.
4. Press the Up button. Use this display to view the Hours in
Service since the last regeneration cycle. This option setting is
identified by “HR” in the upper left corner of the screen.