background image

Limited Warranty:

 Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of 

original shipment.  In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.  

THE WARRANTY SET FORTH HEREIN IS GIVEN ExPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODuCT.  THE COMPANY MAKES NO OTHER 

WARRANTIES, ExPRESS OR IMPLIED.  THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, ExPRESS OR IMPLIED, INCLuDING BuT NOT LIMITED TO THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICuLAR PuRPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special 

or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting 

from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no 

control.  This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.  

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages.  Therefore the above 

limitations may not apply to you.  This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State.  You should consult applicable state laws to 

determine your rights.  

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLuDING THE IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICuLAR PuRPOSE, ARE LIMITED IN DuRATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

WARNING:

 This product contains chemicals known 

to the State of California to cause cancer and birth 

defects or other reproductive harm.

For more information: www.watts.com/prop65

IS-FS-200-W   1517 

EDP#2915183 

© 2015 Watts

USA:

  Tel: (978) 689-6066 • Fax: (978) 975-8350 • Watts.com

Canada:  

Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca

Latin America:  

Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • Watts.com

A Watts Water Technologies Company

Pressure — Temperature

Maximum Service Pressure:  160 psi

Maximum Temperature: 250°F

Enclosure:  NEMA type 1 (for indoor use only). 

Formed sheet metal construction. 

Powder coated cover, zinc plated  

chassis, brass body. Not for use in  

hazardous locations.

Contacts:    SPDT  switch 

7.4 FLA, 44.4 LRA@120VAC Motor Duty

Pilot Duty Rating: 125V@120/240VAC

Ambient Temp. Range: 32°F-176°F (0°C-80°C) 

Media Temp. Range: 32°F-250°F (0°C-121°C)

Pipe Connection: 1"NPT - Brass

Conduit Access: 2 openings for 1/2" conduit

Usage:  1" to 6" pipe sizes  

(see Flow Chart - Table 1)

Installation Instructions

Trimming the Paddles

1.  The stainless steel paddles (set of 4 supplied) 

must be trimmed to the appropriate length for 

the pipe diameter being used. Use the template 

at the right of this page as a cutting guide. 

Follow the curve indicated as closely as pos-

sible. Standard shears or tin snips can be used.

Stacking the Paddles 

2.  After trimming, the paddles must be 

stacked as shown in 

Figure 2

 and 

then screwed onto the stem of the 

flow switch. 

   The correct orientation of the paddles 

to the flow of the fluid is essential.

Installing the Tee 

3.  The Flow Switch must be installed 

in a 1" NPT threaded pipe fitting. If a 

reducing bushing or welded 

fitting is required, the length 

must be kept to a minimum 

to insure that the paddle 

can move freely in the run 

of the pipe without coming 

in contact with the bush-

ing or fitting. Tighten the 

Flow Switch with a 1

5

/

8

box wrench or adjustable 

wrench applied to the 

brass nut only. 

Do not 

tighten by grasping the 

enclosure.

 Allow a 1

3

/

4

" space from the bottom 

of the enclosure to the top of the tee 

(Figure 3)

 

and be sure that the arrow on the side of the 

enclosure is in the direction of the flow.

   The paddle must not touch the inside wall of the 

opposite side of the pipe. If there is any contact, 

additional trimming is required.

Wiring 

4.  ENERGIZE CIRCUIT UPON FLOW

 

  Flow Switch will activate load (alarm, light, relay, 

motor starter, etc.) when flow occurs.
  ENERGIZE CIRCUIT UPON NO FLOW

 

  Flow Switch will activate load (alarm, light, relay, 

motor starter, etc.) when no flow occurs.

 

Adjusting Sensitivity

5.   To 

INCREASE

 

sensitivity 

(switch acti-

vates at a 

lower flow 

rate), turn the 

adjustment 

screw counter-

clockwise. 

To 

DECREASE

 sensitivity (switch activates at 

a higher flow rate), turn the adjustment screw 

clockwise.

NOTICE

NOTICE

FIGURE 2

FIGURE 3

FIGURE 4

COMMON (COM)

FLOW OPENS CIRCUIT (NC)

FLOW CLOSES CIRCUIT (NO)

Содержание FS-200-W

Страница 1: ...th or equipment damage disconnect power supply before installing or servicing control Local building or plumbing codes may require modifica tions to the information provided You are required to consult the local building and plumbing codes prior to installation If the information provided here is not consistent with local building or plumbing codes the local codes should be followed This product m...

Страница 2: ...66 Fax 978 975 8350 Watts com Canada Tel 905 332 4090 Fax 905 332 7068 Watts ca Latin America Tel 52 81 1001 8600 Fax 52 81 8000 7091 Watts com A Watts Water Technologies Company Pressure Temperature Maximum Service Pressure 160 psi Maximum Temperature 250 F Enclosure NEMA type 1 for indoor use only Formed sheet metal construction Powder coated cover zinc plated chassis brass body Not for use in h...

Страница 3: ...ue décès ou endommagement de l équipement débranchez le bloc d alimentation avant l installation ou l entretien de la commande Les codes du bâtiment ou de plomberie locaux peuvent commander des modifications à l information fournie Vous êtes tenu de consulter les codes du bâtiment ou de plomberie locaux avant l installation Si les informations fournies ne sont pas compatibles avec les codes du bât...

Страница 4: ...e utilisation intérieure uniquement Construction en métal en feuille profilé Châssis en acier poudré et galvanisé corps en laiton Ne pas utiliser dans des zones dangereuses Contacts contacteur SPDT Régime de fonctionnement du moteur 7 4 FLA 44 4 LRA à 120 V c a Régime de fonctionnement asservi 125 V à 120 240 V c a Plage de temp ambiante 0 C à 80 C 32 F à 176 F Plage de temp du support 0 C à 121 C...

Отзывы: