Do not use with water that is micro biologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
System is intended to be installed on the cold
water line only.
1 Tank – White (Plastic)
1 Module – White (Filters Pre-Installed)
1 Manual
1 Parts Bag
√ 1 1/4" Hole Saw Bit for Faucet opening *
√ Round Knock out Punch for Stainless
Sinks 1/2” & 1¼” *
√ Adjustable Wrench
√ Sharp Knife
√ 1 / 2" & 5/8" Open End Wrenches
√ Phillips Screw Driver and bit
√ Needle Nose Pliers – Adjustable Pliers
√ Electric Drill
√ 1/8", 1/4" & 3/8" Drill Bits
*Required for faucet installation
Operating Temperatures:
Maximum 100°F (37.8°C)
Minimum 40°F (4.4°C)
Operating Pressure:
Maximum 100 psi (7.0 kg/cm
2
)
Minimum 40 psi (2.80 kg/cm
2
)
pH Parameters:
Maximum 11
Minimum 2
Iron:
Maximum 0.2 ppm
TDS (Total Dissolved Solids)
< 1800 ppm
Turbidity
< 5 NTU
Hardness:
Recommended hardness not to exceed 10
grains per gallon, or 170ppm. System will operate with
hardness over 10 grains but the membrane life may be
shortened. Addition of a water softener may lengthen the
membrane life.
Water Pressure:
The operating water pressure in your
home should be tested over a 24 hour period to attain
the maximum pressure. If the incoming water pressure is
above 100 psi then a water pressure regulator is required.
A booster pump is needed for incomming water pressure
under 40psi.
Copper Tubing:
Reverse Osmosis water should not be run
through copper tubing as the purity of the water will leach
copper causing an objectional taste in water and pin holes
may form in the tubing. Be sure to follow any state or
local regulations during installation.
Operational Parameters
Contents of Reverse Osmosis (RO) System
Tools Recommended For Installation