N°
Default value & other possibilities
01
dEG:
Unit of the temperatures displayed
°
C
Celsius
°
F
Fahrenheit
02
__:__
Selection of the Time clock unit
24H
(24:00)
12H
(12:00 AM /PM)
03
dst:
Daylight Summer time change Summer<->Winter
YES
automatic change according to date.
no
no daylight summer time automatic change.
04
AirC:
Calibration of the internal probe
The calibration must be done after 1 day working with
the same setting temperature in accordance with the
following description:
Put a thermometer in the room at 1.5M distance from
the floor (like the thermostat) and check the real
temperature in the room after 1 hour.
When you enter on the calibration parameter “
no
” is
displayed on the right to indicate no calibration has
made.
To enter the value shown on the thermometer, use the
(-)
or
(+)
keys to enter the real value. Then, press
(Ok)