Benchmark Platinum-Edge [ii]: Operation-Service Manual
CHANGE LOG
OMM-0137_J
• 12/20/2022 Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page
167
of
167
Change Log:
Date
Description
Changed By
5/25/2020
Rev F:
DIR 18-19:
Added
note to turn AERtrim
OFF
before proceeding
with combustion calibration (Section 4.4.1 and 4.4.2, pages 39
and 45).
Added Benchmark 5000N
Clarified
reason for “Dual Fuel” column in Table 4.1
Added wiring schematics, Section 11.
Revised BST Implementation instructions, Section 7.3.
Linley
Thobourne &
Chris Blair
8/20/2020
Rev G:
Revised intro to Combustion Calibration regarding Low NOx,
Section 4.5.
DIR 20-05
: Replace BMK 5000/6000 Pilot Burner (29700) with
P/N
66026
, Sections 4.4 and 8.2.1 ang 8.3. Revised front and
rear refractory instructions, Section 8.9. (ref PIR 1608-3).
DIR 20-23
: Revised Combustion Calibration values for BMK
4000 & 5000N for both Natural gas (Section 4.5.1) and Propane
(Section 4.5.2).
Added BMK 4000 & 5000N tables to Section 3.4: Start/Stop
Levels.
Added removal of air filter bag to startup procedure, Section 4.1
(ref ECN 1687).
Updated Figure 7.2
:
BST, BAS and Field Wiring, Section 7.2
Updated BMK4000-5000N Schematic drawings, Section 11.3.
Revised Figure 8-1d, Ignitor-Injector orientation, Section 8.2.
Chris Blair
12/20/2022
Rev H:
Added values for BMK 750/1000 Dual Fuel models, Sections 3.3,
3.4.1, 4.5.1, 4.5.2, 5.2.1, 5.3.1.
Chris Blair
12/20/2022
Rev I:
Replaced images for 68096 & 68097
Lisa Weiss
1/25/2023
Rev J:
In Table 4-4, corrected the gas pressure range for BMK1000P.
Lisa Weiss
© AERCO International, Inc., 2020