background image

Thank you for your purchase of a state of the art 

Watts Premier Water Treatment system. 

WP-1 LCV Water Treatment System:

Watts Premier WP-1 LCV water treatment system contains a heavy duty lead, cyst 

and VOC filter block. This specialty formulated block is capable of reducing lead, 

cryptosporidium, Giardia, Entamoeba as well as harmful Volatile Organic Chemicals 
(See performance data sheet for complete list of VOC’s).  

It is estimated that

 

VOC’s are 

present in one-fifth of the nation’s water supplies. These water contaminants can enter 

ground water from a variety of sources including localized use of herbicides and pesticides, 

gasoline or oil spills, leaking underground fuel tanks, septic system cleaners, and chemicals 

used in the dry-cleaning industry. See performance data sheet for individual contaminants 
and reduction performance.

 

 

System Maintenance

Just because you can not taste it, does not mean that it is not there. Many contaminants in 

the drinking water are undetectable to the taste. Additionally, over time if you do not replace 

the filter element, other bad tastes and odors will be apparent in your drinking water. This 

is why it is important to change out your filter at the recommended intervals as indicated in 

this system manual. When replacing any of the filter elements, pay special attention to any 

cleaning instructions. Should you have any further questions please refer to our website at 
www.wattspremier.com or call our customer service dept. at 1-800-752-5582.

2

Содержание WP-1 LCV

Страница 1: ... carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure and possible damage to property Refer to enclosed warranty for operating parameters to ensure proper use with your water supply WP 1 LCV Tested and certified by NSF International against NSF ANSI Standard 53 for the reduction of claims specified ...

Страница 2: ...il spills leaking underground fuel tanks septic system cleaners and chemicals used in the dry cleaning industry See performance data sheet for individual contaminants and reduction performance System Maintenance Just because you can not taste it does not mean that it is not there Many contaminants in the drinking water are undetectable to the taste Additionally over time if you do not replace the ...

Страница 3: ...__________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ _________________________________________________________...

Страница 4: ...roceeding with installation 4 Step 1 Mounting System Under Sink a Locate a space under the sink that allows the unit to be mounted close to the cold water supply and allows for easy access during maintenance and filter changes System must be installed to the cold water supply only Allow approximately 2 5cm clearance between the bottom of the filter housing and the floor of the sink cabinet c Using...

Страница 5: ... or liquid soap to keep the hole saw cool during cutting Step 2 Drill a Hole for the Faucet in a Porcelain Sink Punch a Hole for the Faucet in a Stainless Steel Sink Drill a pilot hole Use a 1 2 Hole Punch and an adjustable wrench to punch the hole in the sink Step 5 The faucet can now be installed If mounting faucet to a Stainless Steel Sink you will need a 1 2 Hole Punch The faucet opening shoul...

Страница 6: ...n the locating washer lock washer and brass nut onto the shank Check orientation of faucet then tighten brass nut securely Step 4 Connect blue tube from the filtration system to the faucet shank Place the brass nut onto the tube followed by the plastic sleeve tapered end pointing to the end of tube and then place the plastic insert into the end of the tube Step 5 Insert the assembled blue tube int...

Страница 7: ...art Up A Turn faucet handle to the open position to start the flow of water through the unit Run 7 gallons of water through the unit in order to flush out the normal black carbon fines it will sputter until the air is purged out from the unit Initially the water may appear cloudy which is due to tiny air bubbles and it will clear up shortly Close the faucet when finished B Check for leaks If you h...

Страница 8: ...dle to relieve the water pressure b Remove filter housing from lid by turning it to the left as shown in Figure D c Remove used filter cartridge and discard NOTE Do not discard filter housing o ring d Clean inside of filter housing with warm soapy water and rinse to remove soap e Lubricate o ring with water soluble lubricant i e K Y Jelly or Silicone lubricant NOTE Do not use Petroleum based lubri...

Страница 9: ...Cyst VOC Carbon Block 2 1 113002 Lid 3 1 113019 Housing 10 Blue 4 1 113054 O Ring 5 1 116023 Faucet NON AG 6 1 122036 Flow Control Elbow 7 1 560080 Adapt a Valve 8 1 140004 Tubing 1 4 Blue 4FT 9 1 140007 Tubing 1 4 Green 4FT 6 6 8 9 10 7 2 4 3 5 ...

Страница 10: ...his product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Installer California law requires that this warning be given to the consumer For more information www wattsind com prop65 Substance Percent Reduction Influent Challenge Concentration mg L unless noted Maximum Permissible Product Water Concentration ALACHLOR 98 0 04 0 10 0 00...

Страница 11: ...ZENE see TOLUENE 99 0 015 0 20 0 005 MONOCHLOROBENZENE see CHLOROBENZENE 99 0 077 0 001 PCE see TETRACHLOROETHYLENE 99 0 081 0 001 PENTACHLOROPHENOL 99 0 01 0 10 0 001 PERCHLOROBUTADIENE see HEXACHLOROBUTADIENE 98 0 044 0 001 PROPYLENE DICHLORIDE see 1 2 DICHLOROPROPANE 99 0 080 0 001 POLYCHLORINATED BIPHENYLS PCBs Aroclor 1260 0 01 0 10 0 0005 SIMAZINE 97 0 012 0 10 0 004 SILVEX see 2 4 5 TP 99 0...

Страница 12: ...13 11 ...

Страница 13: ... Swivel Ball Extension Triple Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Massaging Spray Soft Touch Adjustment Pads Anti Scaling Spray Nozzle High Strength Housing Triple Plated Finish Cartridge Life Rating 6 months Part No 107098 White Chrome 39 95 Part No 107...

Страница 14: ...inch 4 Incoming water to the Counter Top cannot exceed 100 degrees F 38 degrees C This warranty does not cover any equipment that is relocated from the site of its original installation This warranty does not cover any equipment that is installed or used outside the United States of America and Canada LIMITATIONS AND EXCLUSIONS WATTS PREMIER WILL NOT BE RESPONSIBLE FOR ANY IMPLIED WARRANTIES INCLU...