background image

Limited Warranty

Warranty Information

To place this appliance under limited warranty, the limited warranty registration card
must be completed and returned within 30 days of installation.

Coverage

 - This limited warranty covers the appliance delivered to the original 

owner when the system is purchased for personal, family, or household use. It is 
intended to cover defects occurring in workmanship or material or both.

Warrantor’s Performance and Length of Limited warranty

 - 

warrants that upon receipt 

from the original owner of any mechanical or electronic part which is found to be defective in material or workmanship, 
warrantor will repair or replace the defective item for 3 years from date of installation.

Warrantor further warrants that upon receipt from the original owner of any media tank/valve body, brine cabinet, found 
to be defective in material or workmanship, warrantor will repair or replace the defective item for 10 years from date of 
original installation.

There are no warranties other than those described in this limited warranty instrument.

This limited warranty does not cover any service call or labor costs incurred with respect to the removal and replace-
ment of any defective part or parts.

Warrantor will not be liable for, nor will it pay service call or labor charges incurred or expended with respect to this 
limited warranty.

In the event the water supply being processed through this product contains bacterial iron, algae, sulphur, tannins, or-
ganic matter, or other unusual substances, then, unless the softener is represented as being capable of treating these 
substances in the softener specifi cations, other additional treatment of the water supply must be used to remove these 
substances before they enter this product. Otherwise, warrantor shall have no obligations under this limited warranty.

This limited warranty does not cover damage to a part or parts of the appliance from causes such as fi re, accidents, 
freezing, or unreasonable use, abuse, or neglect by the original owner. 

This limited warranty does not cover damage to a part or parts of the appliance resulting from improper installation. All 
plumbing and electrical connections should be made in accordance with all local codes and the installation instructions 
provided with the appliance. The limited warranty does not cover damage resulting from use with inadequate or defec-
tive plumbing inadequate or defective house wiring; improper voltage, electrical service, or electrical connections; or 
violation of applicable building, plumbing, or electrical codes, laws, ordinances, or regulations.

This limited warranty does not cover incidental, consequential, or secondary damages.

Any implied warranties on the product described in this limited warranty will not be effective
after the expiration of this limited warranty.

Some states do not allow limitations on how long an implied limited warranty lasts or the exclusion
or limitation of incidental or consequential damages, so the above limitations and exclusion
may not apply to you. This limited warranty gives you specifi c legal rights and you may also
have other rights which vary from state to state.

Содержание Sof-Tek

Страница 1: ...ditioner Watts Premier Inc 1725 W Williams Drive C 20 Phoenix AZ 85027 Phone 800 752 5582 www wattspremier com Fax 623 931 0191 Manual Edition 2 19 08 P N Sof Tek INSTALLATION OPERATION AND MAINTENANC...

Страница 2: ...2 Notes this page left blank intentionally...

Страница 3: ...get the maximum benefit and enjoyment from your particular model We urge you to read this information carefully now and any time a malfunction may occur In most cases these reviews will uncover minor...

Страница 4: ...ILLUSTRATIONS 8 INSTALLATION GUIDE 8 REFERENCE ILLUSTRATIONS 9 PLUMBING CONNECTIONS 9 INSTALLATION AND START UP PROCEDURES 12 SETTING THE CONTROLLER 14 DEMAND REGENERATION 14 HARDNESS SETTINGS 15 ELEC...

Страница 5: ...alt substitute such as potassium chloride in place of water conditioner salt If you start with water conditioner salt you can switch to a salt substitute at any time or vice versa If potassium chlorid...

Страница 6: ...washer drain To prevent back siphoning the installer must provide an adequate air gap or a siphon break See figure 1 5 Electricity The transformer supplied is a standard 120 volt 60 cycle A C for USA...

Страница 7: ...klist items are not satisfactory 2 Do not install if incoming or outlet piping water temperature exceeds 120 degrees Fahrenheit Please see specifications on page 30 3 Do not allow soldering torch heat...

Страница 8: ...Valves To simplify installation and servicing a one piece or a three way bypass valve system is recommended when installing your appliance A bypass system also provides access to untreated water when...

Страница 9: ...eads When the joint is complete there will be a small bead of sealant at the fitting interface indicating a properly joined connection 2 When preparing copper fittings it is al ways advisable to use a...

Страница 10: ...e Illustrations Figure 4 This part may be available through your local Home Improvement store Or you can order it through Watts Premier 800 752 5582 Figure 5 Figure 6 IN BYPASS POSITION IN SERVICE POS...

Страница 11: ...Reference Illustrations Figure 7 Figure 8 Figure 9 PLUGGING IN TRANSFORMER Do not plug transformer into an outlet that is controlled by on off switch ADDING SALT TO THE BRINE CABINET 11...

Страница 12: ...D Also the end of the drain line must be equal in height or lower than the control valve See figure 1 4 Flushing Before placing your appliance in service it is very important to flush the cold water l...

Страница 13: ...ou have an abnormal amount of iron be sure to use salt with an iron cleaning additive 10 Adding Water Salt Be sure to remove any packaging or installation materials before adding salt Next add no more...

Страница 14: ...RECHARGE REGENERATION STATUS Regeneration cycle numbers are shown during regeneration The read out will flash with the cycle number The flashing regeneration numbers are First cycle C1 First Backwash...

Страница 15: ...ime to the correct number If Gallons x 100 was selected 01 100 gallons If Liters x 1000 was selected 01 1 000 liters Pressing and releasing SET will save the hardness number and put the appliance into...

Страница 16: ...button will save the time displayed and advance to the next menu Pressing and releasing the SET button will advance programming to the next step Default is 12 PM 8 Set Reg Time and 02 is now displaye...

Страница 17: ...Setting The Controller Continued Controller Layout Figure 10 17...

Страница 18: ...Parts Diagrams ELECTRONICS AND CABINET Figure 11 18...

Страница 19: ...tem Qty 1 95204 Valve Cover Assembly 1 2 95205 Salt Port Cover 1 3 93245 12 Volt Transformer Power Cord 1 4 95202 Cabinet 1 5 C0700 2 Piece Overflow 1 6 93848 Brine Tubing 3 8 18 7 95203 Support Panel...

Страница 20: ...Parts Diagrams Cabinet and Assemblies Figure 12 20...

Страница 21: ...empty 1 4 93808 End Cap O Ring 2 5 95301T Drive End Cap Assembly w o motor magnet disc 1 6 93870 Screw 4 7 90828 O Ring Small End Cap 1 8 93501 Injector Assembly 1 9 95202 Cabinet 1 10 93835 Sleeve 2...

Страница 22: ...Parts Diagrams Injector Assembly Figure 13 Part Number 93501 Note When working on the injector assembly make sure part 3 aligns properly with the outline marked on part 4 22...

Страница 23: ...t screen and nozzle opening These areas must be free of defects such as tears or pits and be free of debris 4 93221 Injector Nozzle 1 Creates the vacuum that draws the brine solution from the Brine Ca...

Страница 24: ...Parts Diagrams I O Adapter Assembly Figure 14 24...

Страница 25: ...etic field from the Turbine and relays it to the Controller The three wire assembly connecting the black wafer Hall Effect Sensor or the Controller board must not be severely bent folded over cut or b...

Страница 26: ...yed opening which transfers the torque generated by the Drive Motor to the rest of the drive system If the drive system becomes jammed this opening can become rounded causing the gear to turn but not...

Страница 27: ...mbling the O ring should be placed on the Drive End Cap boss and be lubricated with silicone grease A twisting action should be applied along with pressure until the O ring seats See Brine Valve As se...

Страница 28: ...assembly 1 out of the hous ing To remove the brine valve retainer 5 push in and turn clockwise to unlock the retainer CAUTION Do not attempt to remove the retainer with the piston assembly in place Th...

Страница 29: ...Make sure compression nuts are tight 2 H7041 Guide and Lock Set 1 Should not be loose 3 H7039 Float Grommet 2 Should keep float from moving up or down 4 H7040 Bell Float 1 5 H7042 Float Washer 1 6 H7...

Страница 30: ...Notes this page left blank intentionally 30...

Страница 31: ...Parts Diagrams Figure 18 Fill Plug Assembly Tank Bottom ITEM NO QTY PART NO DESCRIPTION 1 1 90238 Fill Plug 2 2 90819 O Ring 31...

Страница 32: ...broom han dle Push the handle into the salt to dislodge the salt bridge No soft water The plumbing bypass valve is in the the bypass position page 6 Place bypass valve in the service position Applian...

Страница 33: ...emove restriction thaw or straighten drain line Should be approximately 8 10 with salt Plugged brine line brine line flow control or air check pages 24 25 Clean flow control air check and brine line C...

Страница 34: ...m 14 5 Pressure drop service flow rate of 4 gpm 4 0 psi Maximum flow rate to drain during regeneration gpm 2 0 Water Pressure minimum maximum psi 20 120 Controller type 4 Button Regeneration time minu...

Страница 35: ...or ganic matter or other unusual substances then unless the softener is represented as being capable of treating these substances in the softener specifications other additional treatment of the water...

Страница 36: ...m to 5 00pm EST Made in USA Manufactured using one or more of the following patent numbers 5 089 140 5 300 230 DES 332 480 DES 331 097 5 116 419 5 157 979 5 378 370 2003 1725 W Williams Dr C20 Phoenix...

Отзывы: