background image

Page 12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start up Instructions

Register by phone, fax, mail or internet.   Watts Premier uses this information only to provide 

you with a filter change reminder service.  Pre-filters should be changed every 6 months and 

the final in-line filter annually.  You may register your system via our web site at 

www.wattspremier.com or call 1-800-752-5582 (within USA only) / FAX#: 623-931-0191. 

For Warranty card Please see page 25-26.

If you have connected your RO system to a refrigerator / ice maker, make sure the ice maker 

is off (do not allow water to flow to the ice maker) until flushing (Step 5) is complete and the 

tank has been allowed to fill completely. Connection from the RO to the ice maker system 

should have an in-line valve installed before the ice maker so it can easily be closed to prevent 

water flowing to the ice maker during start up and periodic maintenance. Your RO tank must 

be allowed to fill up fully in order for the ice maker system to work properly. 

After the Tank has filled, open the RO Faucet to flush the tank completely. You will know that 

the tank is empty when the flow rate from the RO faucet is down to a trickle.  Repeat this step 

two more times.  The fourth tank can be used for drinking. 

Don’t Forget To Register!

Open  the  RO  faucet  and  leave  it  open  until  water  begins  to  trickle  out  (it  will  come  out 

slowly).

Step 4

Turn on the incoming cold water at the angle stop valve.  Open the needle valve on the brass 

Adapt-a-Valve by turning counter clockwise. Check the system for leaks and tighten any fittings 

as necessary.   (Check frequently over the next 24 hours to ensure no leaks are present).

Step 3

Step 2

Note:

Step 1

Close the RO faucet allowing the storage tank to fill with water.

  It may take 4 to 6 hours to 

fill the tank completely depending on the production capability of the membrane, local water 

temperature and water pressure. 

Flushing of the tank 3 times is only necessary during the initial startup and after replacing the 

membrane.

During the fill period you may hear water trickling due to the Reverse Osmosis Process.

Note:

Note:

Congratulations!

You have completed the installation of new your Reverse Osmosis system.

Please Follow the Startup Instructions.

Содержание DELUXE PLUS

Страница 1: ...ax 623 931 0191 Save manual for future reference MODELS Warning Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may l...

Страница 2: ...Page 2 This page has been left blank intentionally...

Страница 3: ...your RO system is a ve micron sediment lter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appearance of your water Stage 2 and 3 Carbon lters rec...

Страница 4: ...d Faucet Installation 7 Adapt a Valve Installation 8 Drain Saddle Installation 8 Drill hole and Connect 3 8 Black Tube from Faucet to the Drain Saddle 9 Green Tube Connection 9 Reverse Osmosis Module...

Страница 5: ...psi 6 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Recommended hardness not to exceed 10 gr...

Страница 6: ...uid soap to keep the hole saw cool during cutting Step 2 Drill a Hole for the Faucet in a Porcelain Sink Punch a Hole for the Faucet in a Stainless Steel Sink Drill a pilot hole Use a 1 2 Hole Punch a...

Страница 7: ...on the rubber gasket item 6 the slotted washer item 7 the white spacer with the open end UP item 8 the hex nut washer item 9 and lastly secure with nut item 11 Step 8 Make sure the plastic delrin sle...

Страница 8: ...in pipe at the best available location Using Phillips screw driver tighten screws evenly and securely on both sides of the drain saddle Keep the plastic compression nut off at this time The small squa...

Страница 9: ...parts bag has 2 self tapping screws Using an electric drill with a Phillips bit screw them into the cabinet wall 6 apart and 16 from the bottom of the cabinet Do not cut any RO system tubes at this ti...

Страница 10: ...s nut plastic sleeve and brass insert from the parts bag To assemble place the brass nut on the tube rst then the sleeve small tapered end of sleeve must point to the end of tube and then insert the b...

Страница 11: ...ting on the nal lter make sure tube is pushed all the way into the tting Tighten with a 5 8 wrench securely Repeat this step to connect the blue tube from the tank into inlet side of the nal lter Step...

Страница 12: ...RO Faucet to ush the tank completely You will know that the tank is empty when the ow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drink...

Страница 13: ...ap solution and rinse with water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be u...

Страница 14: ...r run for 5 more minutes Turn off the incoming water supply to the system by turning the adapt a valve clockwise until it stops Keep the RO faucet open until the storage tank is completely drained Ope...

Страница 15: ...ample Send the samples to the address listed on the cover of this manual attention Water Samples Watts Premier will test the water and mail or call you with the results Note Step 1 Turn off the incomi...

Страница 16: ...n be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet s...

Страница 17: ...ts The empty tank pressure should be 5 7 psi See page 16 4 Noise from faucet or drain Crimp in drain line Check tubing and straighten or repair as necessary Restriction in drain line Straighten all dr...

Страница 18: ...a 101009 CARBONBLOCK 10 5M CTG 3 b 100036 GAC 10 56 Cu In 4 a 110004 MEM 18 GPD 4 b 110009 MEM 25 GPD 5 a 113002 LID BLACK 1 4 FPT 5 b 113005 LID WHITE 1 4 FPT 6 a 113019 HOUSING FILTER 10 BLUE 6 b 1...

Страница 19: ...valent Copper Fluoride Lead Radium 226 228 Selenium Perchlorate 100 ug L 2 None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants not applicable Rated...

Страница 20: ...on 00 1452 5 SV Deluxe CRO TFM 5SV Ultra 5 and Pur Tek Watts 25 Watts RO 4 Watts RO 5 RO TFM 4SV RO TFM 5SV System conforms to NSF Standard 58 for speci c claims This system has been tested according...

Страница 21: ...er from a public water utility contact the utility to nd out if free chlorine or combined chlorine is used in the water system This Watts Premier reverse osmosis system is designed to remove up to 98...

Страница 22: ...The unique top mount design allows for easy above counter installation The Monitored version of this faucet has an LED light that turns red to notify you for lter replacement Part No 116000 Chrome Non...

Страница 23: ...ludes a 10 Final in line Filter Sediment Filter Two Carbon Block Filters and a Filter Wrench Part No 560067 33 95 each Using only the available energy from the brine water otherwise lost to the drain...

Страница 24: ...t Swivel Ball Extension Triple Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement lter De...

Страница 25: ...l enter your information XXXXX XXXXXX Watts Premier Inc is concerned for the safety of your personal information Watts Premier collects personal information when you register with Watts Premier This i...

Страница 26: ...Country USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Instal...

Страница 27: ...e of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2 nd stage Carbon 6 months 3rd stage Carbon 6 months Final Filter Carbon 1 y...

Страница 28: ...coming water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm...

Отзывы: