![Watts Industries WFHTRF-HC Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/watts-industries/wfhtrf-hc/wfhtrf-hc_user-manual_3769605013.webp)
13
used like an external ambiance sensor.
If the external sensor is used as floor sensor, the
thermometer should be put on the floor.
FL
:
Lower limitation of the floor temperature. Only
effective if the external sensor is connected and
selected:
5
°
C
Adjustable From
5°C
to „
FH
“
FH
:
Upper limitation of the floor temperature. Only
effective if the external sensor is connected and
selected:
28
°
C
Adjustable From „
Fl
“ to
37°C
J7
:
Selection of regulation type:
rEg
: Proportional band (PWM)
hys
: Static differential of 0.3°K
CY
: Proportional Integral regulation time cycle
value in minutes: