12
Air
:
Room sensor only or room sensor with
floor limitation if the external sensor is
connected.
Flr:
External sensor only without
limitations.
A0
:
Calibration of the internal sensor
(The calibration must be done after 12Hours
working with the same setting temperature)
- To check the temperature in the room, put a
thermometer at 1.5M distance to the floor in the
concerned room and wait 1 hour to be sure that
the thermometer show the correct temperature.
Then you can enter the value saw on the
thermometer with
(-
◄)
or
(►+)
keys.
F0
:
Calibration of the external sensor.
The calibration must be done same as described
above if the external sensor is connected and