background image

1

Box Contents

• One (1) EW-105-24 or EW-205-24

• Accessory bag:

Cover plate for 4" round outdoor junction box, with two cover plate attachment hole plugs,
cover plate gasket, cover plate screws & screw covers (4 ea), lens mask, wire nuts (3)

• Installation instructions

TABLE OF CONTENTS

DESCRIPTION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

COVERAGE PATTERNS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

MOTION SENSOR PLACEMENT   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Mounting Options   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Mounting and Sensor Positioning Guidelines  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

WIRING AND INSTALLATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Sensor Wire Functions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Connecting to a Power Pack   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Connecting to a DM-105 HID Dimming Module   . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Connecting to a DM-105-WP HID Dimming Module  . . . . . . . . . . . . . . . . . . . . . . . . .6

TESTING AFTER INSTALLATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

DIAL ADJUSTMENTS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

SECURITY OVERRIDE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

TROUBLESHOOTING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

ORDERING INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

WARRANTY INFORMATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

CAUTION

READ ALL OF THE INSTALLATION INSTRUCTIONS 

BEFORE INSTALLING THIS PRODUCT.

THIS UNIT MAY BE USED IN APPLICATIONS WITH DEVICES THAT USE HIGH

VOLTAGE.  IT SHOULD ONLY BE INSTALLED BY QUALIFIED PERSONS THAT ARE

THOROUGHLY FAMILIAR WITH PROPER SAFETY PROCEDURES AND 

ELECTRICAL AND BUILDING CODES FOR THE INSTALLATION LOCATION.

WARNING: TO AVOID FIRE, SHOCK, ELECTROCUTION, OR DEATH—TURN OFF

POWER AT THE CIRCUIT BREAKER OR FUSE BOX AND TEST TO 

ENSURE POWER IS OFF BEFORE WIRING.

Check Our Web Site For FAQs: www.wattstopper.com

Содержание EW-105-24

Страница 1: ...B Series power packs supply power for up to 11 sensors BZ Series power packs supply power for up to 15 sensors DM 105 HID Bi Level control module supplies power for up to 2 sensors DM 105 WP Outdoor...

Страница 2: ...dule 6 Connecting to a DM 105 WP HID Dimming Module 6 TESTING AFTER INSTALLATION 7 DIAL ADJUSTMENTS 7 SECURITY OVERRIDE 9 TROUBLESHOOTING 9 ORDERING INFORMATION 10 WARRANTY INFORMATION 10 CAUTION READ...

Страница 3: ...mounting heights ambient temperature and weather conditions DESCRIPTION The EW sensors are outdoor passive infrared PIR motion sensors rated for wet conditions They install onto standard round outdoor...

Страница 4: ...r plate mounting as shown in the illustration on the right Horizontally mounted For horizontal mounting such as under eaves rotate the sensor housing as shown in the diagrams below Make sure that the...

Страница 5: ...f sheltered locations preferred Aim motion sensor downward to limit sensing Mount motion sensor level Do not mount by vents or above lamps Install sensor no higher than 20 from ground Ideal mounting h...

Страница 6: ...EW 205 24 have 3 wire connections to the power pack or DM 105 or DM 105 WP module See the descriptions and wiring diagrams that follow for connections to each specific power source RED 24VDC input to...

Страница 7: ...om sensor to RED wire from the DM 105 WP cable BLACK common wire from sensor to BLACK wire from the DM 105 WP cable BLUE wire from sensor to WHITE wire from the DM 105 WP cable Control Output from Sen...

Страница 8: ...t may be too high and the sensor s light level adjustment is keeping the sensor inactive Wait until daylight levels have reduced before testing again 5 See Dial Adjustments below for guidelines to adj...

Страница 9: ...l toward the moon icon as desired this lowers the light level setting Remember the sensor must detect motion for lights to turn on The lights turn on high later in the evening The lights turn off low...

Страница 10: ...vement in the coverage area the sensor should turn lights off low in 12 seconds Reset the time delay to the desired value If the lights do not turn off low have a person qualified to check high voltag...

Страница 11: ...24 24VDC 270 Outdoor PIR Motion Sensor includes cover plate BZ 100 Power Pack 120 277VAC 60Hz 150mA 20A ballast or incandescent 1HP 120 240VAC B120E P Power Pack 120VAC 60Hz 150mA 20A ballast 13A inca...

Страница 12: ...Putting a Stop to Energy Waste 2800 De La Cruz Boulevard Santa Clara CA 95050 USA Technical Support 800 879 8585 or 972 578 1699 www wattstopper com 03701r1 12 2003...

Отзывы: