25
xx0x : Set frequency output after process timer finishes counting
xx1x : Zero speed output after process timer finishes counting
Fn_85 ~ Fn_91 : Process timer 1 ~ Process timer 7 = 0 - 3600 sec
1. Inverter will be operated under Jog frequency (Fn_24) when Fn_56 - Fn_58 is set to 3 and
multi-function input terminal is on.
2. Inverter will be operated under multispeed frequency when Fn_56 - Fn_58 is set to 0 - 2 and
multi-function input terminal is on.
3. If Fn_84 = xxx1, Fn_56 - Fn_58 = 0 - 2 or 16 -18 and pulse signal is received on multi - function
input, Inverter will run at a certain time ( set by Fn_85 ~ Fn_91)at a certain frequency (set by
Fn_17~Fn_23) then return to frequency set by keypad or external VR or jump back to 0 speed
(Fn_84=xx1x or xx0x)
4. If Fn_84 = xxx1, Fn_56 - Fn_58 = 14 or 30 and pulse signal is received on multi - function input,
Inverter will operate in process 1
→
2
→
3
→
4
sequence till all process timer is over then returns to frequency set by keypad or external VR or
jump back to 0 speed (Fn_84=xx1x or xx0x).
5. New speed setting and timer can not insert into ongoing timer and speed.
6. Priority of frequency reading is as follows: Jog
→
Multispeed setting
→
Digital operator
frequency set by digital operator or external frequency signal.
Multispeed
terminal 3
multispeed
terminal 2
multispeed
terminal 1
Jog terminal
Output
frequency (Hz)
Operation time
X X X X
Fn_25
X X O X
Fn_17
Fn_85
X O X X
Fn_18
Fn_86
X O O X
Fn_19
Fn_87
O X X X
Fn_20
Fn_88
O X O X
Fn_21
Fn_89
O O X X
Fn_22
Fn_90
O O O X
Fn_23
Fn_91
-- -- -- O
Fn_24
O: TERMINAL ON
X: TERMINAL OFF
-- : NO EFFECT