Lubrication
Use a detergent SAE#10 automotive engine oil. Lubrication is necessary for all moving
parts and rust prevention. We recommend that an automatic air lubricator be installed in
the air line just ahead of the motor.
Automatic lubrication (recommended) - An In-line oiler should be adjusted to feed one
drop per minute for high speed or continuous duty use. Do not overfeed oil as
contamination of the exhaust air may occur.
Manual lubrication - Add 10-20 drops of oil every eight hours of operation through the
inlet port while the pump is shut down.
12 701PB Air motors: troubleshooting
Reason
Low
torque
Low
speed
Won't
run
Runs
hot
Runs well
then
slows
Dirt, foreign material
Internal rust
Misalignment
Insufficient air pressure
Air line too small
Restricted exhaust
Poor lubrication
Jammed machine
Compressor too small
Compressor too far from
unit
Page 11 of 25
Watson-Marlow Bredel E-Manuals
14/12/2009
file://M:\staging\pdfs-global\m-701baseplate-gb-02.htm