Device Related Diagnostic Data
Byte 1, 2, 3, 4, 5, 6*
Mandatory Slave Bytes
8 bit
Byte 7
Header byte
8 bit
Byte 8
Pump model
8 bit
Byte 9
Pump head
8 bit
Byte 10
Tube size (high byte)
8 bit
Byte 11
Tube size (low byte)
8 bit
Byte 12
Min speed (high byte)
8 bit
Byte 13
Min speed (low byte)
8 bit
Byte 14
Max speed (high byte)
8 bit
Byte 15
Max speed (low byte)
32 bit
Byte 16, 17, 18, 19
Software version, Main CPU
32 bit
Byte 20, 21, 22, 23
Software version, HMI CPU
32 bit
Byte 24, 25, 26, 27
Software version, Flash
32 bit
Byte 28, 29, 30, 31
Software version, PROFIBUS CPU
*
Note
: Bytes 1-6 may not be visible, depending on the Master system used.
Channel related diagnostic data
Byte 1
Header
Byte 2
Channel type
Byte 3
Channel related error code
m-730bpn-en-08
27
Содержание 700 Series
Страница 13: ...8 3 Pumphead options 730 pump range 720R 720R RX 720RE 720RE REX m 730bpn en 08 13...
Страница 53: ...m 730bpn en 08 53...
Страница 76: ...21 Help 21 1 Help Select Help from the main menu to access the help screens 76 m 730bpn en 08...
Страница 83: ...Refitting 1 2 3 m 730bpn en 08 83...