The PROFIBUS pump can be integrated into a PROFIBUS DP V0 network using a General Station Data
(GSD) file. The file identifies the pump and contains key data including its communication settings, the
commands it can receive and the diagnostic information it can pass to the PROFIBUS master on
interrogation.
Note
: The data flow to and from the pump may need to be byte reversed, due to the differences of
handling between suppliers of master devices.
The GSD file, file name WAMA0F70.GSD can be found at our website wmftg.com.
User parameter data
The user parameter data is set by entering values into the 'Ext_User_Prm_Data_Const (0)' line of the GSD
file. This is indicated below and the relevant bytes are listed in the table. No further changes should be
made to the GSD file and Watson-Marlow accepts no responsibility for the pump failures arising from the
changes to the GSD file.
Byte
1
Byte
2
Byte
3
Byte
4
Byte
5
Byte
6
Byte
7
Byte
8
Byte
9
8 bit
Byte 1
Pump type
8 bit
Byte 2
Head type
8 bit
Byte 3
Min speed (high byte of 16-bit unsigned)
8 bit
Byte 4
Min speed (low byte of 16-bit unsigned)
8 bit
Byte 5
Max speed (high byte of 16-bit unsigned)
8 bit
Byte 6
Max speed (low byte of 16-bit unsigned)
8 bit
Byte 7
Fail safe mode configuration
8 bit
Byte 8
Fail safe speed (high byte of 16-bit unsigned)
8 bit
Byte 9
Fail safe speed (low byte of 16-bit unsigned)
Examples: Ext_User_Prm_Data_Const(0) =
Pump
type
Pump
head
Fieldbus
min speed
set seed
(high byte)
Fieldbus
min speed
set seed
(Low byte)
Fieldbus
Max
speed
(high
byte)
Fieldbus
Max
speed
(low
byte)
Fail
safe
Fail
safe
speed
(high
byte)
Fail
safe
speed
(low
byte)
0x03
0x80
0x00
0x00
0x00
0x00
0x00 0x00
0x00
= 730 with 720R
head
22
m-730bpn-en-08