![Watson Marlow Pumps 530 Series Скачать руководство пользователя страница 64](http://html2.mh-extra.com/html/watson-marlow-pumps/530-series/530-series_operating-manual_3763085064.webp)
64
m-530sn-gb-02
Error code
Error condition
Suggested action
Er10
Tacho fault
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er14
Speed error
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er15
Over current
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er16
Over voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er17
Under voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er19
Over temperature
Stop pump immediately. Turn OFF. Seek support.
Er20
Signal out of range
Check analog control signal range. Trim signal as
required. Or seek support.
Er21
Over signal
Reduce the analog control signal.
Er30
Over power
Turn OFF. Check power supply. Check pumphead
and tubing. Wait 30 minutes. Power ON may reset.
Or seek support.
Err50
Communication error
Attempt to reset by switching power OFF/ON. Or
seek support.
20.2
Technical support
Watson-Marlow Fluid Technology Group
Falmouth, Cornwall
TR11 4RU
UK
Telephone: +44 (0) 1326 370370
Fax: +44 (0) 1326 376009
Email: [email protected]
Содержание 530 Series
Страница 3: ...27 Trademarks 85 28 Disclaimers 86 29 Publication history 87 m 530sn gb 02 3...
Страница 14: ...14 m 530sn gb 02 8 3 Pumphead options 530 pump range 520R 501RL 313 314 505L 505BA 505CA 314MC 318MC...
Страница 87: ...29 Publication history m 530sn gb 02 530 S SN pump First published 12 15 Issue 2 06 16 m 530sn gb 02 87...