Using the ^/v keys, change the value reported when the sensor input is at 20mA. Once satisfied with the
value press
SELECT.
Depending on the sensor and units selected the maximum values that can be set at below
Pressure Unit
Minimum
Maximum
PSI
-10.0
75
Bar
-0.689
5.171
Flow Unit
Minimum
Maximum
ul/min
0
60000000
ml/min
0
60000
ml/hr
0
900000
l/min
0
60
l/hr
0
900
The Warning / error levels screen will then be shown, refer to
"Set Alarm and Warning level" on
. The error and warning values will default to the value set at 4mA and 20mA. The user should
set up warnings and errors to suit their process.