![Watlow 988 series Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/watlow/988-series/988-series_user-manual_3705897060.webp)
Name
Description
Read (?) and/or Write (=) Syntax
Range
data.1
data.2
Modbus
Address
Dual Channel Controller Prompt Table
996, 997,
998
, 999
7.2
Data Communications with the Watlow Series 988 Family
Command Summary Series 996-999, Chapter 7
A3HI
Output 3 Alarm High ? <sp> A3HI<cr>
Process: A3LO to sensor high range
341
= <sp> A3HI <sp> data.2 <cr>
Deviation: 0 to 9999
°
Default: RH or 999
°
A3LO
Output 3 Alarm Low ? <sp> A3LO <cr>
Process: sensor low range to A3HI
340
= <sp> A3LO <sp> data.2 <cr>
Deviation: -999 to 0
°
Default: RL or -999
°
ACAL Analog Offset
? <sp> ACAL <cr>
-999 to 999
°
F
746
= <sp> ACAL <sp> data.2 <cr>
-555 to 555
°
C
-999 to 999 units
Default: 0
°
F, 0
°
C, 0 units
AL3
Alarm 3 Type
? <sp> AL3 <cr>
0 = Process Alarm, Input 2 (CH B)
736
= <sp> AL3 <sp> data.2 <cr>
1 = Deviation Alarm, Input 2 (CH B)
2 = Process Alarm, Input 1 (CH A)
3 = Deviation Alarm, Input 1 (CH A)
Default: 2
ALM
Alarm Status
? <sp> ALM <cr>
0 = No alarms occurring (0000 0000)
110
(Writing a 0 clears
= <sp> ALM <sp> 0 <cr>
Bit 3 = A3LO
(0000 0100)
next alarm.)
Bit 4 = A3HI
(0000 1000)
110 = Alarm 3
0 = off
1 = HI
2 = LO
ALT
Altitude
? <sp> ALT <cr>
0 = 0
1902
Compensation
= <sp> ALT <sp> data.2 <cr>
1 = 2500 feet
2 = 5000 feet
default: 0
AMB
Ambient Terminal
? <sp> AMB <cr>
Input 1 terminals in 0.0
°
F
1500
Temperature
ANUN Alarm Annunciation ? <sp> ANUN <cr>
0 = off
742
= <sp> ANUN <sp> data.2 <cr>
1 = on
Default: on
AOUT Analog Output 3
? <sp> AOUT <cr>
0 = Retransmit Process Channel A
743
Retransmit Function = <sp> AOUT <sp> data.2 <cr>
1 = Retransmit Set Point Channel A
2 = off
3 = Retransmit Process Channel B
4 = Retransmit Set Point Channel B
Default: 0
ARH
Retransmit
? <sp> ARH <cr>
ARL to 9999
745
Range High
= <sp> ARH <sp> data.2 <cr>
Default: RH1 or RH2 per AOUT
ARL
Retransmit
? <sp> ARL <cr>
-999 to ARH
744
Range Low
= <sp> ARL <sp> data.2 <cr>
Default: RL1 or RL2 per AOUT
ç
CAUTION:
Avoid writing <=>
continuously,
such as ramping
set points or
repetitive loops, to
the Series 996-999
EEPROM memory.
Continuous writes
may result in
premature control
failure, system
downtime and
damage to
processes and
equipment.
Table 7.2 -
A3HI to ARL
NOTE:
The number of
decimal places
returned by many
of these com-
mands is deter-
mined by the
DEC1, DEC2, IN1
or IN2 setting.
Name
Description
Read (?) and/or Write (=) Syntax
Range
data.1
data.2
Modbus
Address
Command Summary Series 996-999 Data Communications