5. Inside the control panel, locate the terminal block (TB-1).
6. Remove existing power cord.
7. Connect the #10 AWG, BLACK wire from the sub-panel 30 amp GFCI breaker [terminal L1] to TB-1 terminal L1.
8. Connect the #10 AWG, WHITE wire from the sub-panel 30 amp GFCI breaker [terminal N, load neutral] to TB-1 terminal N.
9. Connect the #10 AWG, GREEN wire from the sub-panel GROUND bar to TB-1 terminal GROUND.
The GFCI breaker inside the sub-panel supplies all of the power to the spa. Before each use, open the sub-panel and press the TEST
button located on the sub-panel GFCI breaker. The breaker should snap into the “tripped” position and the spa should stop operating.
Reset the sub-panel GFCI breaker by completely pressing the breaker switch down, into the OFF position. Then, flip the breaker switch
up, into the ON position. Power should be restored and the spa should resume operation.
If the GFCI breaker fails to operate in this manner, it is an indication of an electrical malfunction and the possibility of an electric shock.
Disconnect the power until the fault has been identified and corrected.
IMPORTANT:
Should you ever find the need to move or relocate your Solana
™
spa, it is essential that you understand and apply these
installation requirements. Your Solana
™
spa has been carefully engineered to provide maximum safety against electric shock.
Remember, connecting the spa to an improperly wired circuit will negate many of its safety features.
18
™
Содержание Solana
Страница 1: ...Watkins Manufacturing Corporation OWNER S MANUAL...
Страница 2: ......
Страница 61: ...NOTES 59...
Страница 62: ...NOTES 60...