1.

 

Pull out the red clamp and 
remove the brine elbow from its 
port.  

2.

 

Pull the pipe through the nut  

3.

 

Insert the cylindrical insert at the 
end of the tube, then the two 
rings in turn.  

4.

 

Insert the end of the pipe into the 
brine elbow completely and 
tighten by hand.  

5.

 

Insert the brine elbow in its porte 
and put in place the red clamp. 
Note: The brine elbow has a 
sealing ring that can be rotated in 
the direction you want. The 
turning angle is 270 degrees.  

6.

 

Pull the other end of the tube 
through the hole in the side of 
the reagent tank and connect in 
the same way as in points 2, 3 
and 4. When the equipment is 
connected to the water supply, 
sewer, and the brine tank, add 

salt tablets (NaCl) to the reagent tank and 15 liters of water for the first start up. 

 

3.5. Connecting to electricity 

 

The  control  valve  is  supplied  with  an  electrical  transformer  for  220  V.  The  power  supply  to  the 
equipment must be provided at all times. The transformer is only intended for use in dry areas.  

Note:

  All  electrical  connections  must  be  made  in  accordance  with  local  regulations.  Provide 

uninterrupted power supply within 2 meters of the water filter. 
There  is  a  rectangular  socket  at  the  end  of  the  transformer  cable  that  must  be  connected  to  the 
electronic plate on the control valve. To do this, do the following: 
1. Remove the front plastic cover on the control unit.  
2. At the top side on of the control valve, release the middle mounting tab that holds the system 
board frame to the control valve. 
3. The plastic wall of the control valve has an opening on the right side through which the end of the 
transformer cable must be routed.  
4. Connect the end of the cable to the contact port on the bottom right of the motherboard called 
“power”.  
5. The rest of the cable section must be routed along the side of the motherboard frame behind the 
clamps provided.  
6. Slide the control valve board frame back to the mounting tab and secure it in place.  
7. Put back in place the plastic front cover. 
 
 

 

Содержание CMS 10 TWIN

Страница 1: ...tel 371 67381989 e mail info watex eu www watex eu Installation and operating manual WATEX CMS 8 9 10 12 13 14 TWIN CONTINUOUS OPERATION WATER SOFTENING FILTERS Before use please read the manual caref...

Страница 2: ...5 2 3 1 Backflush cycle 6 2 3 2 Brine cycle 6 2 3 3 Second backwash cycle 6 2 3 4 Rinse cycle 7 2 3 5 Fill cycle 7 3 INSTALLATION 8 3 1 General conditions 8 3 2 Connecting to water supply 8 3 3 Connec...

Страница 3: ...LOCATION Please note that the water treatment equipment is heavy and fragile as the fiberglass tank cannot withstand mechanical shocks The same applies to the control unit which has a built in electro...

Страница 4: ...the filter material for the softening plant There is also a collecting pipe in the tank the bottom of which has a sieve with certain gaps to prevent the filter material from entering the water supply...

Страница 5: ...e filter media The duration of the service cycle depends on the quality of the incoming water the amount of filter material and the amount of water consumed If one of the consumers uses water during t...

Страница 6: ...ll not reach the specified capacity and the pressure drop in the filter will increase This mode lasts about 6 8 minutes The flow rate is regulated by a flushing seal DLFC inserted in the drain connect...

Страница 7: ...ipe up and away to the sewer The flow rate is regulated by the flushing seal DLFC inserted in the sewer connection bend The mode lasts for 4 minutes factory setting 2 3 5 Fill cycle In this cycle the...

Страница 8: ...nto the holes in the sleeves and do not strike with a hammer Teflon tape is not required for sewer and reagent addition fittings Position the water filter so that the distance between the drain and th...

Страница 9: ...ecommended to install a sampling tap before and after the equipment to determine the water quality of the untreated and freshly treated water It is also recommended to install manometers before and af...

Страница 10: ...ing water and may cause the unit to rinse incompletely which can lead to poor water quality The sewer hose can also be connected to the sewer system above the control unit max 1 m but then the first r...

Страница 11: ...ied with an electrical transformer for 220 V The power supply to the equipment must be provided at all times The transformer is only intended for use in dry areas Note All electrical connections must...

Страница 12: ...ion In the display correct time can be visible and it does not flash anymore 4 2 Regeneration cycle length and capacity set up Press and hold simultaneously button NEXT and button down for 3 seconds 1...

Страница 13: ...used more than usual such as when there have been guests or more laundry etc To start manual recovery with the set delayed recovery time press and release the REGEN button The words REGEN TODAY will f...

Страница 14: ...ires maintenance during exploitation There is a charge for both warranty and post warranty maintenance Frequency of standard equipment maintenance once a year The frequency of maintenance may vary dep...

Страница 15: ...fy the start of regeneration 1002 or E2 unexpected stop 1003 or E3 Motor runs too long out of adjustment trying to reach the next regeneration cycle position 1004 Motor runs too long out of adjustment...

Страница 16: ...art d Electronic plate damaged d Replace electronic plate 8 Control valve does not make recovery automatically but it does so when REGEN button is pressed a Water flowing through the bypass a Close th...

Отзывы: