background image

WINTERIZING

CARE OF ELECTRIC MOTOR

If the air temperature drops below 35º F. the water in the pump 
can freeze and cause damage. Freeze damage is not warrantable.

To prevent freeze damage follow the procedures listed below.

1. Shut off electrical power for the pump at the house circuit breaker.

2. Drain the water out of the pump case by removing the two drain  
plugs from the case. Store the plugs in the pump basket.

3. Cover the motor to protect it from severe rain, snow, and ice.

4. Do not wrap the motor in plastic. It will cause condensation and rust 
on the inside of the motor.

PROTECT FROM HEAT

1. Shade the motor from the sun.
2. Any enclosure must be well ventilated to prevent overheating.
3. Provide ample cross ventilation.

PROTECT AGAINST DIRT

1. Protect from any foreign matter or splashing water.
2. Do not store (or spill) pool chemicals near the motor.
3. Avoid sweeping or stirring up dust near the motor while it is 
operating.
4. If a motor has been damaged by dirt it voids the warranty.

PROTECT AGAINST MOISTURE

1. Protect from splashing pool water.
2. Protect from the weather.
3. Protect from lawn sprinklers.
4. If a motor has become wet – let it dry before operating. Do not allow 
the pump to operate if it has been flooded.
5. If a motor has been damaged by water it voids the motor warranty.

NOTE: DO NOT wrap motor with plastic or other air tight materials. The motor may be covered during a storm, 
for winter storage, etc., but NEVER when operating or expecting operation.

WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.

 

This pool pump must be installed by a licensed or 

certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable 
local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage 
to property. Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do 
so could result in death or serious injury to serviceman, pool users or others due to electric shock.

WARNING: DO NOT 

open the strainer pot if pump fails to prime or if pump has been operating without water in the 

strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain 
scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal 
injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then with 
extreme caution.

4

Содержание CHAMPS-125

Страница 1: ...be given to the owner operator of this equipment NOTE When pump is mounted permanently within 5 ft of the inside walls of a swimming pool you must use No 8 AWG or larger conductor to connect to bondin...

Страница 2: ...to the terminal board 5 Make sure all electrical connections are clean and tight 6 Permanently ground the motor using the internal green ground terminal located on the inside of the motor canopy or ac...

Страница 3: ...the length of time between filter cleaning it is most important to visually inspect the hair and lint pot basket at least once a week A dirty basket will reduce the efficiency of the filter and heate...

Страница 4: ...re operating Do not allow the pump to operate if it has been flooded 5 If a motor has been damaged by water it voids the motor warranty NOTE DO NOT wrap motor with plastic or other air tight materials...

Страница 5: ...on a flat surface and tap out the carbon spring seal 11 Clean the seal plate seal housing and motor shaft 1 When installing the replacement ceramic carbon seal use silicone sealant on the metal portio...

Страница 6: ...olt Schs 15 805 0238 1 0 Ring 238 16 319 1420 1 Diffuser Plate 17 715 1201 2 3 8 Quarter Slot Plug SdWet End 18 805 0112 2 O Ring 014 20 319 1430 1 Basket Assy 21 805 0436 1 O Ring 6 Trap Lid CHAMPION...

Страница 7: ...ll not prime too much air Remedy a Check suction piping and valve glands on all suction gate valves b Secure lid on pump strainer pot and make sure lid gasket is in place c Check water level to make s...