background image

PUMP STRAINER BASKET

WARNING: DO NOT 

open the strainer pot if pump fails to prime or if pump has been operating without water in the 

strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain 
scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal 
injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then with 
extreme caution.

WARNING: THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATION SYSTEM (e.g. 
LOCK RING, PUMP, FILTER, VALVES, ETC) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED.
PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY
DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.

This unit, sometimes referred to as the “Hair and Lint Pot”, is the unit in front of the volute. The lint pot must be installed using only teflon tape on 
the threads. Do not use liquid chemical thread sealant. The basket inside the chamber must be kept clean of leaves and debris at all times. View 
basket through the “See Through Lid” to inspect for leaves and debris. Regardless of the length of time between filter cleaning, it is most important 
to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and heater and also put an 
abnormal stress on the pump motor which would result in a costly repair bill.

CAUTION: 

To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer 

and skimmer baskets regularly.

1.   Turn off motor.
2.  Relieve pressure in the system.
3.   Turn the lid in a counter-clockwise direction until it stops.
4.   Lift lid and remove basket.
5.   Put the debris from the basket into the trash and rinse out the   
  basket. If the basket is cracked, it should be replaced.
6.   Replace the basket and fill the pump pot and volute up to the 
   inlet port with water.
7.   Clean the cover, O-ring and sealing surface of the pump pot.  
  Grease the O-ring with Teflon or silicone.
8.   Reinstall the lid (Figure 2).
9.   Make sure the lid O-ring is properly placed. Seat the lid then turn  
  clockwise until hand tight (

DO NOT

 over tighten with tools)  

 

  (Figure 3).
10.  Turn the power “ON” at the house circuit breaker. Reset the pool  
  time clock to the correct time.
11.  Open the manual air relief valve on top of the filter.
12.  Stand clear of the filter. Start the pump.
13.  Bleed air from the filter until a steady stream of water comes out.  
  Close the manual air relief valve.

FIGURE 2

FIGURE 3

Lid

O-Ring

Basket

Pot

Lid

Volute

3

Содержание CHAMPS-125

Страница 1: ...be given to the owner operator of this equipment NOTE When pump is mounted permanently within 5 ft of the inside walls of a swimming pool you must use No 8 AWG or larger conductor to connect to bondin...

Страница 2: ...to the terminal board 5 Make sure all electrical connections are clean and tight 6 Permanently ground the motor using the internal green ground terminal located on the inside of the motor canopy or ac...

Страница 3: ...the length of time between filter cleaning it is most important to visually inspect the hair and lint pot basket at least once a week A dirty basket will reduce the efficiency of the filter and heate...

Страница 4: ...re operating Do not allow the pump to operate if it has been flooded 5 If a motor has been damaged by water it voids the motor warranty NOTE DO NOT wrap motor with plastic or other air tight materials...

Страница 5: ...on a flat surface and tap out the carbon spring seal 11 Clean the seal plate seal housing and motor shaft 1 When installing the replacement ceramic carbon seal use silicone sealant on the metal portio...

Страница 6: ...olt Schs 15 805 0238 1 0 Ring 238 16 319 1420 1 Diffuser Plate 17 715 1201 2 3 8 Quarter Slot Plug SdWet End 18 805 0112 2 O Ring 014 20 319 1430 1 Basket Assy 21 805 0436 1 O Ring 6 Trap Lid CHAMPION...

Страница 7: ...ll not prime too much air Remedy a Check suction piping and valve glands on all suction gate valves b Secure lid on pump strainer pot and make sure lid gasket is in place c Check water level to make s...