background image

INSTALLATION INSTRUCTIONS

6. Securely snap all (8) eight oval slot plugs (#3) provided onto the (8) 
eight slots in the drain cover support plate (#8).

This replacement SOFA is only acceptable for use if the
provided fasteners can be installed as intended by these instructions
 Verify proper installation by checking that the sump dimensions
meet the required dimensions shown  for values A through F as 
well as the required pipe size.

7. Attach the drain cover (#2) to the drain cover support plate (#8) 
using the tool and the three 10 x 7/8 security screws provided. Waterway 
requires the use of security screws to secure the cover. Apply 20 In-Lbs 
torque to three Torx Security Screws on the cover. Ensure proper fit and 
no play.

CAUTION: Use only supplied screws to secure the cover. DO NOT 

use power tools.

NOTE: 

For fastener repair, evaluation and replacement - if any of the listed fastener or fastener receptacles in these instructions are damaged in any 

manner such that that the required torque specification cannot be achieved, both the fastener and receptacle parts must be replaced 

4. Align the drain cover support plate and ring over the ring or sump. The 
top of the outlet pipe should be recessed a minimum of 1 inch from the 
back of the plate (Figure 4).

5. Attach the drain cover support plate (#8) to the pool or spa surface 
with the appropriate screws as described in 3 above. Once installed, be 
sure that the drain cover support plate is firmly in place and cannot be 
pulled out of the pool or spa surface.  The Drain cover support must be 
firmly in place or

 DO NOT

 proceed to next step.

Figure 4

810-0257-2017.0521

©2021 Waterway Plastics

Содержание 640-214 V Series

Страница 1: ...CTION OUTLET SUMPLESS 640 214x V 810 0257 2017 0521 2021 Waterway Plastics 2200 East Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 www waterwayplastics com waterway waterwayplastics...

Страница 2: ...chanical entrapment This cover grate shall only be installed on the sump configuration authorized by these instructions SOFA configuration 640 214xV with certified flow rating 178 gpm floor 132 gpm wa...

Страница 3: ...ach operational day During installation ensure components and fastener receptacles are clean free of debris and obstructions Hand check cover grate for snugness to the sump frame wall fitting after in...

Страница 4: ...ing parts must be replaced prior to starting spa or pool pump Never operate spa or pool without drain cover in place and properly affixed death or serious injury can result It is imperative to securel...

Страница 5: ...7 2017 0521 2021 Waterway Plastics A PVC Pipe 2 B Minimum Sump Depth 0 C Minimum Ledge Depth 1 D Minimum LedgeWidth 1 2 E Minimum Pipe Offset 1 2 F Minimum Length Before Reduction 16 Pipe Orientation...

Страница 6: ...or spa we recommend you contact a licensed pool builder or remodeler to install a second point of suction VINYL ULTRA RETRO SUCTION OUTLET IMPORTANT INFORMATION ULTRA RETRO SUCTION OUTLET INCLUDED CO...

Страница 7: ...70V 10 Ultra Retro Suction Cover 3 642 3220A Screw Slot Cover 4 819 0910 10 x 5 8 Self Threading Screw 5 819 0912 10 x 7 8 Self Threading Screw 6 819 0911 10 x 1 1 4 Self Threading Screw 7 819 0999 8...

Страница 8: ...led support plate and ring over the vinyl sump Line up the correct slots with the existing screw holes that were used for the previous grate cover CAUTION If the sump has brass inserts in it for machi...

Страница 9: ...CAUTION Use only supplied screws to secure the cover DO NOT use power tools NOTE For fastener repair evaluation and replacement if any of the listed fastener or fastener receptacles in these instruct...

Страница 10: ...0262 Fax 805 981 9403 www waterwayplastics com waterway waterwayplastics com Designed Engineered Manufactured in the USA 0 0 5 1 1 5 2 2 5 3 3 5 0 20 40 60 80 100 120 140 160 180 Head Loss 20 50 100 F...