background image

   

 

      Plumbing Connection

UDZ

ZDWHULQ

UDZZDWHUWR

RXWVLGHIDXFHWV

FRQGLWLRQHG

ZDWHULQ

KRW

FROG

KRWZDWHUKHDWHU

7ULWRQ%\SDVV9DOYH

Typical Plumbing Installation

STOP

Check local codes 

for minimum run 

between unit and 

water heater

Important: Brass or plastic 

  yoke assembly (not shown) is 

required to connect piping to the 

bypass valve and is available in 

either NPT or solvent.

3

Содержание softmax

Страница 1: ...Owner s Manual SOFTMAX Whole House Water Softener with Triton Electronic Control Valve ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT www watertech com or call 888 254 8412...

Страница 2: ...your equipment This may cause an equipment imbalance or put a strain on plumbing and electrical connections DO NOT disconnect or remove any part of the plumbing or electrical cord DO NOT attempt to re...

Страница 3: ...s located at the rear of the unit is designed to isolate the unit from the plumbing for servicing or to shut off the water supply to the unit in the event of a leak at the conditioner Consult the oper...

Страница 4: ...W FROG KRW ZDWHU KHDWHU 7ULWRQ SDVV 9DOYH Typical Plumbing Installation STOP Check local codes for minimum run between unit and water heater Important Brass or plastic yoke assembly not shown is requi...

Страница 5: ...Nut PolyTube Insert Drain Elbow Locking Clip CAUTION Never connect drain line directly into drain sewer line or trap Always allow an air gap of at least 25mm 1 inch or 2 pipe diameters between the dr...

Страница 6: ...ng brine Continue to skip cycles by pressing and releasing the REGEN button wait for the motor to stop before pressing REGEN until you reach the Brine Fill position This ensures that water will go to...

Страница 7: ...ilding run for several minutes to purge the unconditioned water out of the pipes After several minutes take a water sample and test for hardness from the running tap If a hardness test reads soft wate...

Страница 8: ...s for This is usually referred to as manual regeneration because it is only started manually If there is a period of heavy water usage because of guests or a heavy laundry day for example a manual reg...

Страница 9: ...ll not need to be reprogrammed Step 1 Press SET CLOCK Step 2 Current Time hour Set the hour of the day using the 5 or 6 buttons AM PM toggles after 12 Press NEXT to go to step 3 Step 3 Current Time mi...

Страница 10: ...ding bypass valve illustrations on the following page Figure 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control val...

Страница 11: ...Bypass Valve Illustrations Figure 1 Normal Operation Position Figure 2 Bypass Operation Position Figure 3 Diagnostic Mode Position Figure 4 Shut Off Mode Position 10...

Страница 12: ...otherwarranties expressedorinferred includinganyimpliedwarrantyoffitnessforaparticular purpose Labor and transportation costs incidental to the delivery or replacement of parts other than WTI factory...

Отзывы: