background image

   

Dealer Contact and Product Information

• 

DO alwaYs

 check your state and local regulations regarding plumbing and electrical connections and 

placement of the system before installation.

• 

DO 

install the system into the existing cold water supply line before the water heater and before any cold 

water outlet that requires treatment.

• 

DO

 bypass your system in the event of a water or plumbing related emergency.

• 

DO

 inspect the brine tank monthly, if applicable.

• 

DO

 contact your WaterTech Dealer if you have any questions about the operation of your system or water 

quality issues.

• 

DO

 enjoy all the benefits of your treated water!

• 

DO nOT

 hang or stack items on your equipment. This may cause an equipment imbalance or put a strain 

on plumbing and electrical connections.

• 

DO nOT

 disconnect or remove any part of the plumbing or electrical cord.

• 

DO nOT

  attempt  to  reprogram  your  system.  Your  system  has  been  factory  or  field  programmed 

specifically for your application.

• 

DO nOT

  overfill  the  brine  tank  with  salt.  Approximately  6  inches  below  the  rim  is  the  maximum 

recommended fill.

• 

DO nOT

 allow your system and attached plumbing to be exposed to extreme temperatures (below 40° 

F or above 110° F).

• 

DO nOT

 use with water that is microbiologically unsafe or of unknown quality without adequate 

disinfection before or after the system.

1

   

 

    Do's and Do not's

Dealer Name: 

Dealer Phone Number:                                                                                Installation Date:

Model Number:                                                                Serial Number:

PrODuCT MusT Be reGIsTereD TO aCTIVaTe warranTY

VIsIT www.waTerTeCH.COM or Call 888-254-8412

Содержание softmax

Страница 1: ...Owner s Manual SOFTMAX Whole House Water Softener with Triton Electronic Control Valve ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT www watertech com or call 888 254 8412...

Страница 2: ...your equipment This may cause an equipment imbalance or put a strain on plumbing and electrical connections DO NOT disconnect or remove any part of the plumbing or electrical cord DO NOT attempt to re...

Страница 3: ...s located at the rear of the unit is designed to isolate the unit from the plumbing for servicing or to shut off the water supply to the unit in the event of a leak at the conditioner Consult the oper...

Страница 4: ...W FROG KRW ZDWHU KHDWHU 7ULWRQ SDVV 9DOYH Typical Plumbing Installation STOP Check local codes for minimum run between unit and water heater Important Brass or plastic yoke assembly not shown is requi...

Страница 5: ...Nut PolyTube Insert Drain Elbow Locking Clip CAUTION Never connect drain line directly into drain sewer line or trap Always allow an air gap of at least 25mm 1 inch or 2 pipe diameters between the dr...

Страница 6: ...ng brine Continue to skip cycles by pressing and releasing the REGEN button wait for the motor to stop before pressing REGEN until you reach the Brine Fill position This ensures that water will go to...

Страница 7: ...ilding run for several minutes to purge the unconditioned water out of the pipes After several minutes take a water sample and test for hardness from the running tap If a hardness test reads soft wate...

Страница 8: ...s for This is usually referred to as manual regeneration because it is only started manually If there is a period of heavy water usage because of guests or a heavy laundry day for example a manual reg...

Страница 9: ...ll not need to be reprogrammed Step 1 Press SET CLOCK Step 2 Current Time hour Set the hour of the day using the 5 or 6 buttons AM PM toggles after 12 Press NEXT to go to step 3 Step 3 Current Time mi...

Страница 10: ...ding bypass valve illustrations on the following page Figure 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control val...

Страница 11: ...Bypass Valve Illustrations Figure 1 Normal Operation Position Figure 2 Bypass Operation Position Figure 3 Diagnostic Mode Position Figure 4 Shut Off Mode Position 10...

Страница 12: ...otherwarranties expressedorinferred includinganyimpliedwarrantyoffitnessforaparticular purpose Labor and transportation costs incidental to the delivery or replacement of parts other than WTI factory...

Отзывы: