2 5 Installing the hydraulic unit
2 5 1 Installation precautions
• The room in which the appliance operates must
comply with the prevailing regulations.
• To facilitate maintenance and to allow access to the
various components, we recommend that you provide
sufficient space all around the hydraulic unit.
350 mm
mini
1000 mm
300 mm
mini
(S)
1
2
118 mm
(S)
538 mm
mini
418 mm
mini
300 mm
mini
350 mm
mini
188 mm
figure 13 - Mounting bracket
• Be careful not to bring inflammable gas near to the
heat pump during its installation, in particular when
it requires brazing. The appliances are not fireproof
and should therefore not be installed in a potentially
explosive atmosphere.
2 5 2 Positioning the hydraulic unit
- Fix the support solidly (4 screws and plugs) to a flat,
hard-wearing wall (not a light partition) ensuring that it
is correctly levelled.
- Hook the appliance onto its support.
Installation and operating manual "1532 - EN"
- 15 -
Air to Water Heat Pump