background image

 

 

                                                                                                                                                   

                                                                                                                                         

Softener Specifications

-Pre-Installation Check List-

A water test should always be performed

 in order to determine total water hardness (in gpg) and total dis-

solved iron (in parts per million - ppm). This is critical for proper equipment selection, sizing and for determining 
the program for regeneration frequency. If heavy concentrations of iron (above 5 ppm), iron coloration, iron bac-
teria or sediment are present, filtration prior to the softener will most generally be required. Certain states may 
require a licensed plumber for installation.

Note :  Flexible water supply connectors and flexible drain line tubing may not be allowed in you locale. Please 
check with local plumbing code officials prior to installation.

Installation Requirements

•  A level floor position ahead of piping into water heater.
•  Unit must be installed at least 10’ ahead of the inlet to a water heater to prevent damage due to 
   back-up of hot water.
•  DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur!
   (See Installation Diagrams for proper placement and plumbing connections.)

-Major System Components-

1. 

Brine Tank

 - This tank holds the salt that is added to the softener. This salt is dissolved with water to form a  

    brine solution used in the softener regeneration process.
2.

 Resin Tank

  - This tank contains the ion exchange resin media. Water flows through the resin tank under pres 

    sure to come into contact with the resin for water softening.
3. 

Control Valve

 - The valve directs water through the resin tank for water softening and controls the flow of

    water / brine for the regeneration process.

Installation

5

Содержание AS24P

Страница 1: ...Softener Manual Installation Operation Manual Fully Automatic Demand Water Softeners with 2092 Isobar Control Valve...

Страница 2: ...Softener Specifications Page 3 Softener Installation Page 5 Softener Capacity Page 10 Installing the Control Valve Page 13...

Страница 3: ...ations 3 General Specifications AS24P AS24VP DS24P DS24VP AS32P AS32VP DS32P DS32VP AS48P AS48VP DS48P DS48VP AS64P AS64VP DS64P DS64VP Grains Capacity lbs Salt Per Regeneration 24K 12 19K 6 32K 15 30...

Страница 4: ...t water The surfaces of these beads are covered with sodium ions As hard water enters the mineral tank and comes into contact with the resin an ex change of ions takes place as dissolved Calcium and M...

Страница 5: ...llation Requirements A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO N...

Страница 6: ...d All plumbing lines not requiring soft water should be connected upstream of the softener The brine tank drain line is gravity flow and must discharge below the overflow fitting The brine overflow is...

Страница 7: ...on the control valve are 3 4 FNPT 1 FNPT for AS96V DS96V units Caution Raised arrows located on the sides of control valve body and bypass valve indicate proper direction of water flow Install inlet...

Страница 8: ...ss water to the drain and prevent flooding of the floor Therefore no liability will or can be assumed by the manufacturer of the softener should this occur Electrical Connection 1 Plug the cord from t...

Страница 9: ...hart beginning on page 8 that corresponds with the capacity of the softener 4 Select the salt setting to be used and use this section of the capacity chart NOTE Salt settings are pre set at the factor...

Страница 10: ...of People with the Compensated Hardness to find the number of tabs to slide When you have determined the number of tabs to slide consult the regeneration frequency chart below to find the actual tab...

Страница 11: ...61 75 2 4 6 12 12 12 NOTE All of these charts assume 75 gallons per person per day usage Regeneration Frequency Slide Out TAB NUMBER of Tabs Out 1 2 3 4 5 6 7 8 9 10 11 12 12 6 4 3 2 1 Model Nominal 3...

Страница 12: ...2 12 71 80 2 3 6 6 12 12 12 12 81 90 2 4 6 12 12 12 12 91 100 2 4 6 12 12 12 Model Nominal 64 000 Grain Units 64 of People 1 2 3 4 5 6 7 8 9 Salt Setting 30 lbs Regeneration Hardness Range Number of P...

Страница 13: ...tal parts per million ppm by four 4 and then add to the grains per gallon gpg of hardness Use this compensated hardness level when programming the regeneration frequency WARNING DO NOT reduce salt set...

Страница 14: ...ne tank when sediment appears in the bottom of the salt compartment 7 Always keep the brine tank supplied with good quality salt a type designed for use in water softeners Servicing Instructions Chang...

Страница 15: ......

Страница 16: ...710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com...

Отзывы: