background image

 

 

                                                                                                                                                   

                                                                                                                                         

WARNING

Lubricants

Do NOT use Vaseline, oils, hydrocarbon lubricants or spray silicone anywhere! Petroleum base lubricants will 
cause swelling of o-rings and seals. The use of other lubricants may attack plastic Noryl®. It is recommended that 
Dow Corning® silicone grease be used as a lubricant for all control valves. Dow Corning® 7 Release Compound 
is used in the manufacture of Chandler Systems control valves. (Part # LT-150)

Sealants

Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials. It is recommended 
that Teflon® tape be used to seal plastic Noryl® threaded fittings.

Softener Specifications

3

General

Specifications

AS24P

AS24VP

DS24P

DS24VP

AS32P

AS32VP

DS32P

DS32VP

AS48P

AS48VP

DS48P

DS48VP

AS64P

AS64VP

DS64P

DS64VP

Grains Capacity / lbs. 

Salt Per Regeneration 

24K / 12

19K / 6

32K / 15

30K / 12

22K / 6

48K / 23

44K / 18

33K / 9

63K / 30

59K / 24

44K / 12

Grains Capacity / lbs. Salt Per Generation 

with Vortech

24K / 7.5

32K / 9

48K / 15

64K / 18

Maximum Raw Water Hardness (grains)

50

75

100

100

Maximum Clear Iron/Manganese (ppm)

3

5

5

5

Cation Exchange resin (cu. ft.)

0.75

1

1.5

2

Mineral Tank (polyglass)

8 x 44

9 x 48

10 x 54

12 x 52

Brine Tank (polyethylene w/ grid)

18 x 33

18 x 33

18 x 33

18 x 33

Service Flow Rate (gpm)

7

8

10

12

Backwash Flow Rate (gpm) / Vortech

1.5 / 1.2

2.0 / 1.5

2.4 / 2.0

3.5 / 2.4

Space Required (D x W x H) in inches

18 x 26 x 51

18 x 27 x 55

18 x 28 x 61

18 x 30 x 59

Approximate Shipping Weight

88 lbs. 

100 lbs.

133 lbs. 

164 lbs.

Содержание AS24P

Страница 1: ...Softener Manual Installation Operation Manual Fully Automatic Demand Water Softeners with 2092 Isobar Control Valve...

Страница 2: ...Softener Specifications Page 3 Softener Installation Page 5 Softener Capacity Page 10 Installing the Control Valve Page 13...

Страница 3: ...ations 3 General Specifications AS24P AS24VP DS24P DS24VP AS32P AS32VP DS32P DS32VP AS48P AS48VP DS48P DS48VP AS64P AS64VP DS64P DS64VP Grains Capacity lbs Salt Per Regeneration 24K 12 19K 6 32K 15 30...

Страница 4: ...t water The surfaces of these beads are covered with sodium ions As hard water enters the mineral tank and comes into contact with the resin an ex change of ions takes place as dissolved Calcium and M...

Страница 5: ...llation Requirements A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO N...

Страница 6: ...d All plumbing lines not requiring soft water should be connected upstream of the softener The brine tank drain line is gravity flow and must discharge below the overflow fitting The brine overflow is...

Страница 7: ...on the control valve are 3 4 FNPT 1 FNPT for AS96V DS96V units Caution Raised arrows located on the sides of control valve body and bypass valve indicate proper direction of water flow Install inlet...

Страница 8: ...ss water to the drain and prevent flooding of the floor Therefore no liability will or can be assumed by the manufacturer of the softener should this occur Electrical Connection 1 Plug the cord from t...

Страница 9: ...hart beginning on page 8 that corresponds with the capacity of the softener 4 Select the salt setting to be used and use this section of the capacity chart NOTE Salt settings are pre set at the factor...

Страница 10: ...of People with the Compensated Hardness to find the number of tabs to slide When you have determined the number of tabs to slide consult the regeneration frequency chart below to find the actual tab...

Страница 11: ...61 75 2 4 6 12 12 12 NOTE All of these charts assume 75 gallons per person per day usage Regeneration Frequency Slide Out TAB NUMBER of Tabs Out 1 2 3 4 5 6 7 8 9 10 11 12 12 6 4 3 2 1 Model Nominal 3...

Страница 12: ...2 12 71 80 2 3 6 6 12 12 12 12 81 90 2 4 6 12 12 12 12 91 100 2 4 6 12 12 12 Model Nominal 64 000 Grain Units 64 of People 1 2 3 4 5 6 7 8 9 Salt Setting 30 lbs Regeneration Hardness Range Number of P...

Страница 13: ...tal parts per million ppm by four 4 and then add to the grains per gallon gpg of hardness Use this compensated hardness level when programming the regeneration frequency WARNING DO NOT reduce salt set...

Страница 14: ...ne tank when sediment appears in the bottom of the salt compartment 7 Always keep the brine tank supplied with good quality salt a type designed for use in water softeners Servicing Instructions Chang...

Страница 15: ......

Страница 16: ...710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com...

Отзывы: