Connecting the Priming Components
1
2
Auto-Prime Push Button Switch
Use the illustration and instructions to connect the
standard push button switch to the priming pump
cable.
1 Connect the priming pump connector
(DT04-2P) on the switch to the priming pump
connector (DT04-4P).
2 Connect the pressure switch connector
(DT06-2S) on the switch
to the pressure switch
connector (DT04-2P).