45
|
56
Connecting the Priming Components
1
2
4
3
Priming Pump and Priming Valve
Use the illustration and instructions to make the
connections on a single priming pump and single
priming valve application.
1 Install the outlet muffler if it is suitable to your
application. Alternatively, locally source the
components required in your application to
direct the priming-pump exhaust away from
people to avoid injury and equipment to avoid
damage.
Note:
Make sure to use a minimal bend radius
and arrange the hose to allow proper
draining.
2 Install a 3/4-inch NPT fitting with a 3/4-inch
hose connection to the priming pump inlet.
3 Install a 3/4-inch NPT fitting with a 3/4-inch
hose connection to the priming valve outlet.
4 Use an appropriate hose to connect to the
fittings on the priming pump and priming valve.
Refer to:
"Hose and Tubing Requirements"
to select the appropriate hose.
Make sure that you install the hose so that it
drains from the priming valve to the priming
pump.