22
|
56
Priming Valve Solenoid Extension Cable
This cable extends the distance between the push button switch and the priming valve solenoid install location.
Note:
The inclusion of this cable is dependent on
your configuration. It is also available separately if required by your application.
2
1
3
Feature
Feature
Description
Description
1 Connector
This connects to the push button switch—DTM04-2P.
2 Cable
This cable length is 120 inches (3048 mm).
3 Connector
This connects to the priming-valve solenoid—DTM06-2S.