112
|
217
Product Overview
Operation
Connecting the Hydraulic Reservoir Sensors, Suction Strainer, and Hydraulic Pump
1
5
2
3
4
Use the illustration and instructions to connect the
hydraulic reservoir sensors, reservoir sensor, and
the hydraulic pump to the control box.
1 Assemble the filter head, filter, and oil-life
indicator. Locally source an appropriate size
and length of pipe to install the filter to the
hydraulic reservoir and connect the hydraulic
hoses. Refer to:
2 Install the temperature sensor into the
accessory ports and connect it to the PDM
control box—the ATF temperature connection.
Note:
Use additional M12 cable extensions if
necessary.
3 Install reservoir level sensor into the reservoir
and connect it to the PDM control box—AFT
tank level connection.
Note:
Use additional M12 cable extensions if
necessary.
4 Install the suction strainer to the reservoir and
connect the hydraulic hoses. Refer to:
"Hydraulic Hoses—Overview" on page 97
5 Install the concentrate pump into the apparatus
and connect the hydraulic hoses. Refer to:
"Hydraulic Hoses—Overview" on page 97
Use the concentrate pump cable to connect the
pump to the PDM control box—the hydraulic
control connection.
Note:
Use additional M12 cable extensions if
necessary.
I-2258 L-1222-8