Product Overview
Operation
Connecting the Tellurus Display
2
3
4
1
Use the illustration and instructions to connect the
Tellurus display.
1 Connect the compatible connector on the
Tellurus HMI cable assembly to the Tellurus
display connector.
2 Connect the compatible connector on the
Tellurus HMI cable assembly to the display
extension cable connector.
3 Connect compatible connector on the display
extension cable to the PDM control box—the
Tellurus HMI CANbus connection.
Note:
Use a CANbus extension cable if
necessary.
4 Locally source a Deutsch DT06-3S connector
and an appropriate cable to connect apparatus
power to the receptacle on the Tellurus HMI
cable assembly. Power the node controller
through a
10 A
circuit breaker.
I-2256 L-1222-6