Waterous Aquis Foam Manager Скачать руководство пользователя страница 4

F

1031, Section 2414

Page 4 of 8

System Components

Table 1. System Components

Ref. No.

Description

1

Aquis

t

 Foam Pump (Proportioner)

2

Foam Pump Inject Valve

3

In

line Foam Concentrate Strainer

Ref. No.

Description

4

Aquis

t

 Foam Pump OIT (Control Panel)

5

Aquis

t

 Operation Instruction Panel Plate

6

OIT Cable

Figure 1. System Components

1

2

4

3

To Foam Tank

5

3

6

Items Shipped Loose

with Aquis Foam Pump

IL3436

Optional Items from Waterous

Description

Foam Tank Level Switch

Aquis Rating Panel Plate

Aquis System Schematic Panel Plate

OIT (Control Panel) Extension Cable

Operation

A pumper equipped with a Foam Manager

t

 foam unit can

be operated in water only and/or foam modes. It is pos­

sible to pump water from one discharge and foam solution
from another discharge.

Water Only Operations

All unit operations begin with pumping water. See the fol­
lowing instruction for details on how to operate and pump
water from your Waterous fire pump:

·

F-1031, Section 2114, 

Operation and Maintenance

Instructions for Waterous CMU Series Centrifugal Fire
Pumps

or

·

F

1031, Section 2115, 

Operation and Maintenance

Instructions for Waterous CS and CSU Series Centrif-
ugal Fire Pumps

CAUTION

Overheating hazard. 

May cause damage to the pump.

Running the unit without adequate water flow or an

overheated water supply can cause damage to the

pump.

Содержание Aquis Foam Manager

Страница 1: ...ice and Maintenance 6 Maintenance Schedule 6 Location of Maintenance Items 6 Advantus Foam Pump 6 Oil Fill and Drain 6 In line Foam Concentrate Strainer 6 Calibration 7 Aquis Foam Pump 7 Troubleshooting Guide 8 Foam Manager with Advantus Waterous Company 125 Hardman Avenue South South St Paul Minnesota 55075 USA 651 450 5000 Instructions subject to change without notice Visit us at www waterousco ...

Страница 2: ... with pump intake or pump discharge connec tions relieve pressure by opening drains or bleeder valves Bleeder valves should also be used while filling a hose connected to an intake with water WARNING Scalding Water Hazard May result in serious burns When operating the pump be sure to open at least one discharge valve slightly to prevent the pump from overheating If the pump runs for a few minutes ...

Страница 3: ...he ideal water to concentrate ratio for superior foam Foam Pump The 12 or 24 volt electric motor driven positive displace ment triplex plunger foam pump is equipped with an alu minum crankcase ball bearings forged brass pump body and manifold solid ceramic plungers stainless steel check valves and piston guides Buna packing and preset thermal and pressure relief valves The foam pump is rated at 2 ...

Страница 4: ...able Operation A pumper equipped with a Foam Managert foam unit can be operated in water only and or foam modes It is pos sible to pump water from one discharge and foam solution from another discharge Water Only Operations All unit operations begin with pumping water See the fol lowing instruction for details on how to operate and pump water from your Waterous fire pump F 1031 Section 2114 Operat...

Страница 5: ...P and DOWN simultaneously when the Total Product is displayed resets the Total Product accumulator to Zero Pressing both UP and DOWN simultaneously for two 2 seconds when the Flow Rate is displayed enters the MANUAL mode of operation See Manual Mode operation below Pressing both UP and DOWN simultaneously while in Mix will go to the preset default FOAM Pressing the FOAM button will alternately sta...

Страница 6: ... Flushing System Change Foam Pump Model Level from Top of Oil Fill Port Capacity Required for Oil Change Use Oil Daily or After Each Use Annually Aquis 2 5 1 4 inch 6 mm 90 quarts Total capacity is 1 0 quart Synthetic 10W 30 Mobil 1 recommended Monthly Depending on the corrosiveness of the foam concentrate to be used flushing of the foam injection circuit may be necessary Most Class A foam concen ...

Страница 7: ...ill allow for calibration of the water flow in the units of measurement selected D F3 Flow Rate Calibration 1 Press the SELECT button at the F3 prompt The current measured flow rate will be displayed Es tablish a flow using an accurate flow measuring device 2 Once this is established press the UP or DOWN but ton to advance to the calibration step If the displayed flow rate is correct press the SEL...

Страница 8: ...dition applies to tanks utilizing a common wall s between the foam tank and the water tank If a leak is confirmed repair the foam tank and flush the water tank and pump until foam is cleared Foam proportioning manifold check valve mal function If the above conditions have been corrected the final cause for foam in the water tank may be the result of a malfunctioning foam manifold check valve To tr...

Отзывы: