System Components
Table 1. System Components
Ref. No.
Description
1
Advantus
t
Foam Pump (Proportioner)
2
Foam Pump Inject/Bypass Valve
3
In
−
line Foam Concentrate Strainer
Ref. No.
Description
4
Foam Manifold
5
Advantus
t
Foam Pump OIT (Control Panel)
6
Advantus
t
Operation Instruction Panel Plate
7
OIT Cable
Figure 1. System Components
1
4
2
5
3
To Foam Tank
6
3
7
Items Shipped Loose
with Advantus Foam Pump
IL3001
Operation
A pumper equipped with a Foam Manager
t
foam unit can
be operated in water only and/or foam modes. It is pos-
sible to pump water from one discharge and foam solution
from another discharge.
Water Only Operations
All unit operations begin with pumping water. See the fol-
lowing instruction for details on how to operate and pump
water from your Waterous fire pump:
•
F
−
1031, Section 2114,
Operation and Maintenance
Instructions for Waterous CMU Series Centrifugal Fire
Pumps
or
•
F
−
1031, Section 2115,
Operation and Maintenance
Instructions for Waterous CS and CSU Series Centrif-
ugal Fire Pumps
CAUTION
Overheating hazard.
May cause damage to the pump.
Running the unit without adequate water flow or an
overheated water supply can cause damage to the
pump.