background image

GUARANTEE OF CORRECT INSTALLATION

NOTE TO CUSTOMER

Your Watermill Shower will only work properly if it has been installed correctly. Ask your installer to

complete the following check list, ensuring it is signed and dated.

NOTE TO INSTALLER

While you are installing this shower tick the following “impor tant instructions” to confirm to both

yourself and your customer this shower has been correctly installed.

If you need assistance please contact Watermill on the Ser vice Helpline 01883 730339.

The shower must be installed in line with current water regulations and I.E.E. Regulations.

When the installation is completed please sign and date the Guarantee of Correct Installation and

then pass to customer to keep.

IMPORTANT INSTRUCTIONS

1.

Do not connect shower to water mains pressure. The shower 

cannot

be used

with combination boilers.

2.

The shower must have a supply head of at least 1 metre. The height from the

top of the water in the cold water storage tank must be at least 1 metre

above the inlet to the shower.

3.

a) Do not use any jointing compounds, abrasive compounds will cause seal to leak.

b) When making pipe joints do 

NOT

allow 

ANY

solder flux to come in contact

with plastic par ts of the shower. The plastic will be corroded and cause

serious leaks.

4.

Complete all pipework before making electrical connections.

5.

After completing installation, the whole system must be thoroughly tested,

operating both hot and cold at full flow. Also check water temperature

stability. Then thoroughly check 

each

connection is tight and not leaking.

6.

Maximum hot water temperature must not exceed 60˚C (130˚F). The hot

water supply to the shower must 

NOT

be connected to the hot water cylinder

expansion pipe.

7.

Please ensure that the installer has explained the correct operation of

the shower.

Signed:

Date:

Company:

If the shower installation does not conform to these instructions, the shower guarantee may be

invalidated and the cost of any “on site” visits by the Watermill Ser vice Depar tment will be

charged for.

WATERMILL PRODUCTS LTD

FAIRVIEW INDUSTRIAL ESTATE, HOLLAND ROAD, HURST GREEN, OXTED, SURREY RH8 9BD

CUSTOMER SERVICE HELPLINE TEL: 01883 730339

ML 311 3/05

Printed in England

14

Содержание Osprey II Series

Страница 1: ...POWER SHOWERS Models 4500M 5002M 4500T 5002T II Performance Shower Products CUSTOMER SERVICE HELPLINE 01883 730339...

Страница 2: ...HE SHOWER 1 4 INSTALLATION Manual Model 2 5 WATER CONNECTIONS Manual Model 3 6 INSTALLATION Thermostatic Model 4 7 WATER CONNECTIONS Thermostatic Model 4 8 ELECTRICAL CONNECTIONS 6 9 ELECTRICAL CONNEC...

Страница 3: ...ation boilers 3 A minumum supply head of 1 metre is required The water level in the cold water storage tank should be 1 metre above the unit 4 Do not use any jointing compounds such as Boss White Abra...

Страница 4: ...of 40mm 15 8 It is recommended that a plywood base 10 12mm thick be cut to the shape of the outline and mounted on the wall behind this to give a flat mounting base There must be a clearance of 1 2mm...

Страница 5: ...nd the cold supply to the top inlet The Osprey power shower can be connected via the either the side entry or back entry To gain access for back entry the access panel must be removed cut with a trimm...

Страница 6: ...pipework if the back access is to be used First screw part way in the 2 top mounting screws while the 3rd bottom screw is inserted After completing installation of the mounting screws screw firmly int...

Страница 7: ...h a knife as shown in Fig 8 Side Entry Measure and cut pipes using a pipe cutter not a hacksaw to correct length place pipe entry covers on pipes and push firmly into push fit connection the pipe must...

Страница 8: ...ompliance with I E E Wiring Regulations BS 7671 If in doubt seek professional advice or assistance from a qualified electrician In the interests of safety it is recommended that a residual current dev...

Страница 9: ...the cable restraint The installation kits are supplied with 5 metres of low voltage connecting lead The connecting leads between the pump and the isolating transformer can be extended up to about 15 m...

Страница 10: ...the lower end of the riser rail into the bottom bracket locating its slot over the tongue in the aperture and press down the collar and disc to snap them home 9 Using a screw attach the top bracket th...

Страница 11: ...set in mid position allowing water to flow for several minutes Check for leaks on supply pipe connections DO NOT TURN ON ELECTRICITY SUPPLY UNTIL FRONT COVER HAS BEEN INSTALLED PROCEED WITH COMPLETIO...

Страница 12: ...ose without handset hang into shower tray or bath c Position temperature control knob in mid position Note The movement of the temperature control can be quite firm as the temperature setting is moved...

Страница 13: ...rewdriver as shown in Fig 29 iii Using a sharp knife cut off one segment of the limit stop as shown in Fig 30 iv Replace temperature limit stop into control knob as shown in Fig 31 making sure to loca...

Страница 14: ...e position until the next time the shower is used There is no need to set to cold position The first time the shower is used there may be some residual air in the system This may cause uneven flow spi...

Страница 15: ...ls it will self reset D POOR WATER FLOW Clean handset spray plate E CUSTOMER SERVICE HELPLINE For advice during installation or assistance with any problems contact the Customer Service Helpline on 01...

Страница 16: ...bove the inlet to the shower 3 a Do not use any jointing compounds abrasive compounds will cause seal to leak b When making pipe joints do NOT allow ANY solder flux to come in contact with plastic par...

Страница 17: ...EW INDUSTRIAL ESTATE HOLLAND ROAD HURST GREEN OXTED SURREY RH8 9BD WATERMILL PRODUCTS LTD WATERMILL HOUSE FAIRVIEW INDUSTRIAL ESTATE HOLLAND ROAD HURST GREEN OXTED SURREY RH8 9BD Name Address Model No...

Страница 18: ...unning or any damage resulting from faulty installation is not covered by the guarantee The integrity of the connections of the pump to the water supply and the shower system is the responsibility of...

Отзывы: