WL2FL
User Manual
Page 6
–
Revision EU19-09-2020
and is not intended for use where water is microbiologically unsafe or with water of unknown
quality without adequate disinfection. System is designed for the supplemental bactericidal
treatment of public drinking water, or other drinking water, which has been tested and deemed
acceptable for human consumption by the state or local health agency having jurisdiction. The
system is designed to reduce normally occurring non-pathogenic or nuisance microorganisms only.
System is not intended for treatment of contaminated water.
WARNING!
TIP HAZARD.
Dispenser could tip or fall causing serious injury. Always install unit on
a firm, flat, and level surface and secure the
WL3 FW Water Treatment System
to the base cabinet
with the screw provided to lock the components together. Secure unit to cabinet, wall, or floor if
needed.
Never place heavy items on top of unit and never climb, stand, or hang on unit or storage cabinet
to prevent injury and damage.
WARNING!
UNIT IS HEAVY. TWO PERSON LIFT REQUIRED.
Transport unit empty and always
use material handling equipment or two people with proper lifting technique to reduce injury risk.
WARNING!
STORE AND TRANSPORT UNIT EMPTY. ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
CAUTION!
INDOOR USE ONLY.
Intended for household use only. Never expose to direct
sunlight, heat sources, or ambient air temperature above 32°C (90°F) or below 2°C (35°F). Install
indoors and keep unit away from humidity levels above 65%. Never expose to freezing
temperatures. Ensure there is adequate clearance around the unit to allow refrigeration system
condenser to dissipate heat. Warmer environments require more clearance around the unit.
Minimum clearance around all surfaces of the machine is 50mm. Installs where the ambient
temperature exceeds 25°C, require a minimum of 100mm clearance for proper heat dissipation and
efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR.
Waterlogic will not be responsible for injury
or damage caused by excessive water pressure. Input or feed pressure must be 2.5 bar (36 psi) to
3.5 bar (51 psi). Be aware of any potential pressure surges caused by building/municipal pumping
stations. Water block devices and external leak detectors are strongly recommended. Locate the
unit as close to the water supply and the electrical connections as possible to minimize risk.
CAUTION!
USE PROPER SUPPLY LINES AND FEED WITH POTABLE AMBIENT WATER ONLY.
Feed water over 32°C (90°F) may damage the treatment components. Always use supply lines with
adequate pressure rating and UV resistance. Close water supply valve and contact service
representative if a leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.